NHIE and State Exam Measurements with all Correct &
100% Verified Answers |Actual Complete Update |
Already Graded A+

Flammable items should not be located closer than ___ ___ inches from the water heater.
✔Correct Answer-18

Single wall vents require at least _____ _____ of clearance from any combustible material.
✔Correct Answer-6 inches

Double wall vents (or "B" vents) require at least ____ ____ of clearance from any combustible
material. ✔Correct Answer-1 inch

A properly connected water heater will have a flexible gas appliance connector, no more than
____ ____ in length, connecting the water heater to the gas pipe. ✔Correct Answer-6 feet

For proper ventilation for crawl spaces, the IRC requires ___ foot of screen vent for every ___
sqft of space. ✔Correct Answer-1, 150

Crawl space opening minimum: ___ inches x ___ inches. ✔Correct Answer-18, 24

Attic should have an opening of __ inches by __ inches or headroom of less than __ inches.
✔Correct Answer-22, 30, 30

IRC requires safety glass (or safety glazing) for windows that meet all the following
requirements:
- They are more than __ sqft.
- The bottom of the glass is __ inches or less from the floor, and the top of the glass is greater
than __ inches above the floor.
- There is a __-inch walkway on either side of the glass. ✔Correct Answer-9, 18, 36, 36

A chimney must extend at least ___ ___ higher than any portion of a building within ___ feet,
and at least ___ ___ above where it passes through the roof. (3) ✔Correct Answer-2 feet, 10,
3 feet

Decks that are ___ ____ or higher above ground must have a guardrail on all open sides that is
at least ___ ____ high. ✔Correct Answer-30 inches, 36 inches

The space between baluster, spindles, and rails must be less than ___ inches. ✔Correct
Answer-4

, Treads should be at least _____ inches deep. ✔Correct Answer-10

Outdoor hot tubs listed as "self contained for above ground use" and that are at least ___ ___
above the ground are not required to be bonded to a grid. ✔Correct Answer-28 inches

Well head should stick above the ground, usually at least __ inches. ✔Correct Answer-12

The space above the cooktop, required by IRC is a vertical clearance of __ inches between a
cooktop and combustible materials (including cabinets. ✔Correct Answer-30

With the oven, a temperature difference of more than __ degrees over 350, should be reported
as a deficient. ✔Correct Answer-25

Gas connectors must be less than ______ feet in length. ✔Correct Answer-6

A properly installed gas shutoff valve will be connected to the appliance's supply line within
_____ feet of the appliance. ✔Correct Answer-6

A transition duct for a clothes dryer must be visible and no longer than ___ feet. ✔Correct
Answer-8

The clothes dryer exhaust duct may be made of metal, with No. ___ gauge thickness, a diameter
or ___ inches, and a smooth interior finish. And supported at least every ___ feet. ✔Correct
Answer-28, 4, 12

The length of the clothes dryer duct to the termination point should be less than ___ feet.
✔Correct Answer-35

Thick plywood, OSB, or particle board sheets for subflooring can be ____ - ____ thick.
✔Correct Answer-5/8' - 3/4'

Doors should hang in their frames with a clearance of __/___" on the top and sides with __/__"
at the bottom. ✔Correct Answer-1/8", 3/4"

Copper tubing must be supported horizontally every __ feet, Copper piping every __ feet, and
steel piping every __ feet. ✔Correct Answer-6, 12, 12

The main vent stack must extend __ inches or more above the roof. ✔Correct Answer-6

The roof vent must be __ inches away from any wall or vertical surface and __ feet from any
window, to avoid sewer gases expelled through vent. ✔Correct Answer-12, 10

The TPR valve is set to discharge if temperature exceeds ___ degrees or pressure exceeds ___
psi. ✔Correct Answer-210, 150

Document information

Uploaded on
August 9, 2026
Number of pages
5
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Stuvia2026
2.3
(3)
Sold
26
Followers
1
Items
6412
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions