The energized slot is bigger. True or false? ✔Correct Answer-False, the energized slot is
smaller.

A ____________ receptacle is the most common 120 volt receptacle. ✔Correct Answer--
Duplex receptacle

A duplex receptacle accommodates _____ plugs. ✔Correct Answer-- 2

Based on industry standards, a receptacles is _______ in. from the floor. ✔Correct Answer--
12 in.

Based on industry standards, a receptacles is _______ in. from the floor when serving as a
countertop receptacle. ✔Correct Answer-- 45 in.

Conductors should be secured _____ in. from the box? ✔Correct Answer-- 18 in.

EGC stands for __________ ___________ ____________. ✔Correct Answer-- Equipment
grounding conductor

Receptacles & switches should be connected to the _______? ✔Correct Answer--EGC

Three slot receptacles may not be _____________? ✔Correct Answer-- Ungrounded

Describe the 2 solutions for an ungrounded receptacle. ✔Correct Answer-1) Install GFCI and
label it "no equipment ground"
2) Install EGC to nearest EGC on another branch circuit or o panelboard

A dishonest practice in which a wire is installed between the receptacles EGC terminal (i.e.,
ground, bare conductor) and the ungrounded neutral terminal (i.e., neutral, white conductor) is
called a _________ __________. ✔Correct Answer--bootleg (bad) ground

A bootleg ground does not negatively impact the electrical system. True or false? ✔Correct
Answer-False, a bootleg ground can energize the grounding system.

In order to evenly distribute the load among a branch circuits, a permanently installed appliance
should not exceed ______ % of a general lighting branch circuits amperage rating. ✔Correct
Answer-- 50%

, In order to evenly distribute the load among a branch circuits, a plug installed appliance should
not exceed ______ % of a general lighting branch circuit amperage rating. ✔Correct Answer--
80%

Following the "no point more than 6 ft." rule, the receptacle spacing works out to about every
_______ ft. ✔Correct Answer-- 12 ft.

The max height for a required wall receptacle is 66 in. True or false? ✔Correct Answer-- 66 in.

Measuring horizontally, no point along a countertop wall should be more than _____ in. from a
receptacle. ✔Correct Answer-- 24 in.

Receptacles are always required behind sinks and cooking appliances. True or false? ✔Correct
Answer-False, unless there is more than a 12 in. ledge behind the appliance.

If a receptacle is located above a countertop in an appliance garage (e.g., open ✔Correct
Answer-- Should not be located more than 20 inches above the countertop

If a island is longer than 2 ft. & wider than 1 ft., it requires ______ GFCI receptacles?
✔Correct Answer-- 1 GFCI

Receptacles mounted on a island or peninsula should not be more than _____ in. below the
countertop. ✔Correct Answer-- 12 in.

1 GFCI should be located within 4 ft. of the edge of the bathroom sink. True or false?
✔Correct Answer-False, 1 GFCI receptacle should be located within 3 ft of the edge of the
bathroom sink
-may be mounted on the cabinet if it is no more than 12 inches below the countertop
-none above bathtubs or showers, or flush mounted on countertops

Receptacles can be installed side of a vanity if within ____ in. from the countertop? ✔Correct
Answer-- 12 in.

List the 2 locations receptacles can not be installed in a bathroom. ✔Correct Answer-1) Above
bathtubs & showers (i.e., within the tub/shower surround)
2) Flush mounted on countertop

___________ GFCI receptacles are required in the laundry room. ✔Correct Answer-- At least 1

A receptacle is required if a hall exceeds _____ ft. in length. ✔Correct Answer-- 10 ft.

A receptacle is required in a foyer if the sq. ft. exceeds ____ ft. ✔Correct Answer-- 60 ft.

Document information

Uploaded on
August 8, 2026
Number of pages
5
Written in
2026/2027
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Stuvia2026
2.3
(3)
Sold
26
Followers
1
Items
6412
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions