Cylinders stored within a residential building, including the basement or
any storage area in a common basement of a multiple-family building
and attached or detached garages, shall be limited to cylinders each with
a maximum water capacity of _______ and shall NOT exceed 5.4 lb
aggregate water capacity per each living space unit. - CORRECT ANSWER
✔✔2.7 lbs
All new Class I permit holders must provide bulk storage capacity of
NOT less than an aggregate of ___________ water gallons. - CORRECT
ANSWER ✔✔18,000
LP-gas containers shall be located __________ unless specifically
allowed to be inside. - CORRECT ANSWER ✔✔Outside buildings
Effective January 1, 1993, a ________ shall be applied to all portable
refillable LP-Gas cylinders of 100 lbs or less NOT filled on site. -
CORRECT ANSWER ✔✔Warning Label
A Type B or Type L gas vent shall terminate at least _________ in
vertical height above the highest connected appliance draft hood or
flue collar. - CORRECT ANSWER ✔✔5 feet
, lO M oARcPSD| 69811638
All appliances using electrical controls shall have the controls
connected into a ________. - CORRECT ANSWER ✔✔Permanently live
circuit
All LP gases shall be _______ prior to delivery with a warning agent
down to a concentration in air of NOT over 1/5 the lower flammability
limit. - CORRECT ANSWER ✔✔Odorized
All metallic equipment and components that are ______ shall be coated
or protected and maintained to minimize corrosion. - CORRECT
ANSWER ✔✔Buried or mounded
The upper flammability limit of propane vapor is _____. - CORRECT
ANSWER ✔✔9.6
A sniff test is done to ______ when LP-gas is delivered to the bulk plant.
- CORRECT ANSWER ✔✔Detect odorization
A clearly identified and accessible switch or circuit breaker shall be
installed at a location NOT less than _______ or more than 100 feet
from the dispensing device to shut off power in the event of a fire,
accident, or other emergency. - CORRECT ANSWER ✔✔20 feet
ANSWERS 2026
, lO M oARcPSD| 69811638
Cylinders stored within a residential building, including the basement or
any storage area in a common basement of a multiple-family building
and attached or detached garages, shall be limited to cylinders each with
a maximum water capacity of _______ and shall NOT exceed 5.4 lb
aggregate water capacity per each living space unit. - CORRECT ANSWER
✔✔2.7 lbs
All new Class I permit holders must provide bulk storage capacity of
NOT less than an aggregate of ___________ water gallons. - CORRECT
ANSWER ✔✔18,000
LP-gas containers shall be located __________ unless specifically
allowed to be inside. - CORRECT ANSWER ✔✔Outside buildings
Effective January 1, 1993, a ________ shall be applied to all portable
refillable LP-Gas cylinders of 100 lbs or less NOT filled on site. -
CORRECT ANSWER ✔✔Warning Label
A Type B or Type L gas vent shall terminate at least _________ in
vertical height above the highest connected appliance draft hood or
flue collar. - CORRECT ANSWER ✔✔5 feet
, lO M oARcPSD| 69811638
All appliances using electrical controls shall have the controls
connected into a ________. - CORRECT ANSWER ✔✔Permanently live
circuit
All LP gases shall be _______ prior to delivery with a warning agent
down to a concentration in air of NOT over 1/5 the lower flammability
limit. - CORRECT ANSWER ✔✔Odorized
All metallic equipment and components that are ______ shall be coated
or protected and maintained to minimize corrosion. - CORRECT
ANSWER ✔✔Buried or mounded
The upper flammability limit of propane vapor is _____. - CORRECT
ANSWER ✔✔9.6
A sniff test is done to ______ when LP-gas is delivered to the bulk plant.
- CORRECT ANSWER ✔✔Detect odorization
A clearly identified and accessible switch or circuit breaker shall be
installed at a location NOT less than _______ or more than 100 feet
from the dispensing device to shut off power in the event of a fire,
accident, or other emergency. - CORRECT ANSWER ✔✔20 feet