1. The function of the compressor is : - Answer B. to lower the pressure in the evaporator so that the refrigerant temperature is lowered below the temperature of the air in the box . 2 . Forced air evaporator coils are commonly used because : - Answer A. they absorb more heat in less time . 3 . Evaporator A operates with a 5 ° TD and evaporator B operates with a 15⁰ TD . - Answer D. Box A operates with higher humidity than box B 4 Whenever you re soldering refrigerant lines : - Answer D. B & C 5 . R404A must be charged into a system : - Answer A. In a liquid state 6 . If an evaporator fan motor needs to be replaced it must be replaced with : - Answer C. Any motor with the exact HP , speed , voltage , mounting and rotation 7 . The fan blade on an evaporator or condenser must be positioned in the housing or shroud so that : - Answer B. The blade is mounted mid way into the evaporator housing opening or fan shroud opening on a condenser . 8. Which of the following refrigerants is an interim choice for a replacement for R - 12 in a system that had a leak in the condenser and lost all of its refrigerant ? - Answer C. R - 409A 9 . Which refrigerant is an interim refrigerant choice for a R502 system that had a major leak in the evaporator - Answer d . R408A 10 . When evacuating a refrigeration system what tool is needed to ensure a good evacuation and to help inform you if there is any moisture or leaks in the system : - Answer B. Micron gauge 11 . Which refrigerant would you convert a walk in freezer to if replacing the condensing unit on an R502 system : - Answer B. R404A

Content preview

CFESA- Refrigeration Certification -
Test -Questions with Actual Detailed
Answers 2026 Update.
1. The function of the compressor is : - Answer B. to lower the pressure in the evaporator so
that the refrigerant temperature is lowered below the temperature of the air in the box .



2 . Forced air evaporator coils are commonly used because : - Answer A. they absorb more
heat in less time .



3 . Evaporator A operates with a 5 ° TD and evaporator B operates with a 15⁰ TD . - Answer D.
Box A operates with higher humidity than box B



4 Whenever you re soldering refrigerant lines : - Answer D. B & C



5 . R404A must be charged into a system : - Answer A. In a liquid state



6 . If an evaporator fan motor needs to be replaced it must be replaced with : - Answer C. Any
motor with the exact HP , speed , voltage , mounting and rotation



7 . The fan blade on an evaporator or condenser must be positioned in the housing or shroud so
that : - Answer B. The blade is mounted mid way into the evaporator housing opening or fan
shroud opening on a condenser .



8. Which of the following refrigerants is an interim choice for a replacement for R - 12 in a
system that had a leak in the condenser and lost all of its refrigerant ? - Answer C. R - 409A



9 . Which refrigerant is an interim refrigerant choice for a R502 system that had a major leak in
the evaporator - Answer d . R408A



10 . When evacuating a refrigeration system what tool is needed to ensure a good evacuation
and to help inform you if there is any moisture or leaks in the system : - Answer B. Micron
gauge



11 . Which refrigerant would you convert a walk in freezer to if replacing the condensing unit on
an R502 system : - Answer B. R404A

, 12 . Which phrase best describes the proper use for a refrigerated box using a cap tube system ?
- Answer A. Storage freezer



13 . Which is the best example of the definition of a storage box ? - Answer A. A freezer on
which the door is opened 8 times a day



14 . In order to maintain proper temperature under the various loads , a cooler or freezer
located on a front prep line must be equipped with : - Answer C. A thermal expansion valve



15 . A cap tube is ineffective on most commercial refrigeration systems because : - Answer D. it
cannot respond to the refrigerant needs under heavy loads



16 . The sensor bulb on a TEV must be : - Answer C. mounted tight to a clean surface on the
suction line close to the outlet of the coil



17 . An automatic expansion valve does not : - Answer C. react well in situations of heavy loads
.



18 . For maximum efficiency the thermal expansion valve superheat for a freezer should be
about : - Answer A. 5 degrees



19 . For maximum system efficiency the TEV superheat for a cooler should be about : - Answer
C. 8-10 degrees



20 . What type of oil is most commonly used with CFC refrigerants ? - Answer C. Mineral



21 . What type of oil must be used with R404A ? - Answer D. Polyolester



22 . What pressure relates to 20 ° F on R404A ? - Answer 56.7 psi



23 . What should be the maximum head pressure for a R404A system operating in a 85 ° F
ambient temperature ? - Answer 294 psi



24 . A system with R134A is operating at 146 psi head pressure . The temperature measured
four inches out of the condenser is 100 ° F . The ambient air temperature is 80 ° F . - Answer D.
the subcooling is 10 °



25 . A system operating with refrigerant R404A has a suction pressure of 29 psi . The head
pressure is 239 psi . The temperature on the line out of condenser is 85 degrees. The

Document information

Uploaded on
August 6, 2026
Number of pages
11
Written in
2026/2027
Type
Exam (elaborations)
Contains
Unknown
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TestSolver9
3.6
(181)
Sold
1001
Followers
131
Items
31938
Last sold
3 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions