Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 7 pages
Exam (elaborations)

Automotive service technician- Electrical 2-Questions and Answers.

Document preview thumbnail
Preview 2 out of 7 pages

To connect an ammeter into a circuit, the ammeter - Answer must be connected in series with the circuit A circuit that is controlled by four switches wired in parallel - Answer Can be energized by any one of the four switches The first step in a diagnostic strategy should always be: - Answer Verify the customer concern A diagnostic strategy is - Answer Based on logic and a repeatable series of steps To diagnose a circuit problem when you don't have a symptom chart you should: - Answer Have the wiring diagram for the circuit A true of a delta-wound stator - Answer There is no neutral junction Alternating current in a generator is rectified by: - Answer Diodes Automotive generators with three stator windings generally use how many diodes? - Answer 6 diodes What is the field winding of an automotive type generator part of? - Answer It is part of the rotor What do voltage regulators regulate? - Answer They regulate the voltage that an automotive generator produces Generator output is directly related to: - Answer Field strength and rotor speed Most voltage regulators operate in the range of: - Answer 13.0 to 15.5v To properly check for parasitic drain - Answer Ammeter in series Internal voltage regulator are: - Answer Unserviceable and must be replaced if defective

Content preview

Automotive service technician-
Electrical 2-Questions and Answers.
To connect an ammeter into a circuit, the ammeter - Answer must be connected in series with
the circuit



A circuit that is controlled by four switches wired in parallel - Answer Can be energized by any
one of the four switches



The first step in a diagnostic strategy should always be: - Answer Verify the customer concern



A diagnostic strategy is - Answer Based on logic and a repeatable series of steps



To diagnose a circuit problem when you don't have a symptom chart you should: - Answer
Have the wiring diagram for the circuit



A true of a delta-wound stator - Answer There is no neutral junction



Alternating current in a generator is rectified by: - Answer Diodes



Automotive generators with three stator windings generally use how many diodes? - Answer 6
diodes



What is the field winding of an automotive type generator part of? - Answer It is part of the
rotor



What do voltage regulators regulate? - Answer They regulate the voltage that an automotive
generator produces



Generator output is directly related to: - Answer Field strength and rotor speed



Most voltage regulators operate in the range of: - Answer 13.0 to 15.5v



To properly check for parasitic drain - Answer Ammeter in series



Internal voltage regulator are: - Answer Unserviceable and must be replaced if defective

, A generator drive belt in poor condition and not tensioned properly - Answer Undercharged
battery and squealing noise after the engine started



As battery voltage drops during cranking, current flow: - Answer Increases



Relays can be tested for: - Answer Proper resistance across the solenoid coil and a voltage
drop not exceeding 0.2 volts across the contacte



Starter motor should not be cranked for more than - Answer 30 seconds



Starter motor current draw test, cranking voltage should not drop - Answer 9.6v



An acceptable voltage drop across the starter ground circuit should not exceed what value if the
starter draws 150amps - Answer 0.2v



Excessive drive pinion to flywheel teeth clearance that is too tight - Answer Excessive starter
noise



Starter drives prevent armature overspin through the use of - Answer Overrunning clutch



A starter drive pinion is shifted into mesh with the ring gear by - Answer Solenoid plunger and
shift fork



Starter Solenoid consists of two set of windings known as - Answer Pull-in and hold-in



A starter relay is used to: - Answer Complete the circuit between the battery and starter
solenoid



Starter solenoid performs two jobs for the starter motor - Answer Engage the drive
mechanism and close a switch between the battery and motor terminals



As the starter motor armature spins, its speed is controlled or limited by: - Answer The CEMF
and mechanical loads



Describe the internal resistance in a starter motor - Answer The resistance is very low

Document information

Uploaded on
August 6, 2026
Number of pages
7
Written in
2026/2027
Type
Exam (elaborations)
Contains
Unknown
$12.29

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TestSolver9
3.5
(168)
Sold
980
Followers
129
Items
31418
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions