COMPLETE PRACTICE QUESTIONS AND
CORRECT ANSWERS WITH DETAILED
EXPLANATIONS COMPREHENSIVE HVAC
CONTRACTOR LICENSE EXAM STUDY
GUIDE
Refer to the electrical schematic drawing section labeled "A" represents
a. The complete unit
b. The power distribution
c. The control circuit
d. The resistive loads - CORRECT ANSWER-The power distribution
Refer to the house 2 drawing. The total glazing for this house is
a. 123
b. 48
c. 133
d. 110 - CORRECT ANSWER-133
Refer to the house 2 drawing. What is the net heat gain on the south facing
windows?
,a. 1155 btuh
b. 945 btuh
c. 1034 btuh
d. 1525 btuh - CORRECT ANSWER-1155 btuh
Refer to the house 2 drawing. The net winter heat loss for the ceiling in
bedroom 1 is? Select the nearest answer.
a. 4224 btuh
b. 547 btuh
c. 687 btuh
d. 422 btuh - CORRECT ANSWER-422 btuh
In general the depth of a swagged copper joint should be approximately
____ of the tube size
a. Length
b. Circumference
c. Diameter
d. Same - CORRECT ANSWER-Diameter
Condensate drain pipe can be made of
a. PVC
, b. Galvanized steel
c. CPVC
d. All of the above - CORRECT ANSWER-All of the above
Refrigerant circuit access ports located outdoors shall be fitted with
a. Service caps
b. Locking type tamper resistant caps
c. Sealant
d. Pipe dope - CORRECT ANSWER-Locking type tamper resistant caps
A condensing appliance shall have a ___ where damage can occur
a. Clean out
b. Auxiliary drain pan
c. Trap
d. Tight connection - CORRECT ANSWER-Auxiliary drain pain
Which of the following refrigerant groups would a technician not be
allowed to solder the joints?
a. A1
b. A2
c. B2