Large items, such as pipe, will have the product marking
True
aflxed to the item itself
The local AHJ should be consulted regarding the code
edition and code requirements used where the system is True
to be installed
According to the 2015 UPC, vitrified clay pipe or fittings
shall be used above-ground or where pressurized by a False
pump or ejector
After caulking, the finished joint should not be more than
True
1/8" below the rim of the hub on the cast iron pipe
Galvanized pipe and fittings are for underground instal-
lations only and must be installed at least 6" below the False
ground
Sealant should be placed on male pipe thread's only True
ABS schedule 40 solvent cemented pipe should be sup-
False
ported every 8 feet for all sizes
PVC pipe and fittings manufacture to ASTMF794 -03 are
not suitable for above or underground installation within True
the building structure
The approval of alternate drainage materials by the AHJ
in one jurisdiction does not mean the approval of these True
alternate materials in other jurisdictions
PP - R services are extremely smooth and otter low flow
True
resistance
The only fitting allowed to decrease the size of pipe in the
False
direction of waste water flow is an increaser
Horizontal drainage lines connecting with other horizontal
False
drainage lines should use only 90 degree sweep fittings
1/4