GUIDE 2026 QUESTIONS AND 100% VERIFIED
ANSWERS | GRADED A+ | GUARANTEED PASS!!
A shower spray unit with a hose of ___ long minimum that can be used as a fixed-
position shower head and as a hand-held shower shall be provided.
- answer-59 inches
Bathtubs with permanent seats the back wall shall have to grab bars, one ___ to
___ from the ground, and the other located ___ minimum and ____ maximum
above the rim of the bathtub.
- answer-33 to 36 inches
8 to 10 inches
Bathtubs with permanent seats the control end wall will have a grab bar ____ long
minimum.
- answer-24 inches
Clearance around a water closet shall be ___ minimum measured perpendicular
from the side wall land ___ minimum measured perpendicular from the rear wall.
- answer-60 inches
56 inches
Clearance in front of bathtubs shall extend the length of the bathtub and shall be
___ inches.
- answer-30 inches
Controls for faucets shall be operated with ___ ___.
- answer-one hand
Controls shall be between the ___ ___ and ___ ___, and between the open side of
the bathtub and the centerline of the width of the bathtub.
- answer-Bathtub rim and grab bar
Controls, other than drain stoppers, shall be located on an ___ ___.
- answer-end wall
, drinking fountain spout shall provide a flow of water ___ high minimum and shall
be located ___ maximum from the front of the unit.
- answer-4 inches
5 inches
Drinking spout outlets shall be ___ maximum above the finish floor or ground.
- answer-36 inches
Each grab bar shall be installed ___ maximum from the head end wall and ___
maximum from the control end wall.
- answer-15 inches
12 inches
Flush controls shall be ___ ___ or ___.
- answer-hand operated or automatic.
Flush controls shall be located on the ___ ___ of the water closet, except in
ambulatory accessible compartments complying with 604.8.2.
- answer-open side
Grab bars shall be provided on the side wall ___ to the water closet and on the rear
wall.
- answer-closest
Grab bars shall not be required to be installed in a toilet room for a single occupant
accessed only through a private office and not for ___ use or ___ use.
- answer-common use or public use
Hand-operated metering faucets shall remain open for ___ minimum.
- answer-10 seconds
In a transfer type compartments, grab bars shall be provided across the control wall
and back wall to a point ___ from the control wall
- answer-18 inches
In residential dwelling units, grab bars ___ ___ be required to be installed in toilet
or bathrooms.
- answer-shall not