A ______________ should be used where installation are
located in areas
subject to high water tables of flooding. -
ANSWER-Anchoring
During installation, tank vents and other openings that are
not liquid-tight
should be extended above the ____________ flood-stage
water level until
piping is complete. - ANSWER-
Maximum
A primary method of restraining tanks in areas subject to
flooding is to
___________ the burial depth - ANSWERS-A. level
B. Increase
C. Decrease
D. Diminish
Anser b
,The ________________ and _______________ of the tank are
the most
significant factors that determine the buoyancy of the
tank. - ANSWER-
Diameter,
Capacity
A tank shipped with a liquid filled __________ or with an
interstice on which
a vacuum is drawn, need not be subjected to the instillation
air/soap test -
ANSWER-
interstice
. Filter fabrics are ______________ designed to prevent
movement of back
fill materials, while permitting water to pass through -
ANSWER-Geotextiles
If dissimilar back fill material, such as sand and pea gravel, are
used in the same excavation, separate them with a ________
_____________ - ANSWER-
Fabric filter
If water ballast is used to sink a tank in a wet hole, the level of
ballast in the tank should not _____________ the level of water
in the hole. - ANSWERS-A.
Meet
,B. Exceed
C. Fall short of
D. Be inferior of
Answer B
When adding ballast to an excavation what is the only type
of equipment
that should be used _____________. -
ANSWER-Lifting
All methods of anchoring tanks used the weight of the back-
fill and paving
on top of the tank to offset ____________ forces. -
ANSWER-buoyancy
Weight can be added to the top of a buried tank to offset
____________ -
ANSWER-
Buoyancy
A bottom hold-down pad usually consists of ___inches of
reinforced concrete that extends at least ____inches beyond
the tank sides and one foot beyond each end. - ANSWER-8,18
Straps for steel tanks should be either nonmetallic or _________
________.
- ANSWER-flat
steel
, In all cases, the set-points for overfill "alerts, " such as alarms
or ventrestricting devices, should not exceed 90% of capacity
and the set-points for
product delivery shutdown through flapper-valve-type devices
should not exceed ____%. - ANSWER-95%
Secure the straps to anchor points with - ANSWERS-A.
Anchor bolts
B.
Turnbuckles
C. Wire
cables
D. All of the
above
Answer D
Slope concrete away from spill-containment man holes
to prevent
______________ from entering. -
ANSWER-Water
The manhole should provide flexibility between the fill pipe and
the manhole
assembly to
___________
****** - ANSWERS-A. Be able to bend if pressure is exerted
during filling.