HVAC Gas Heat Exam UPDATED ACTUAL QUESTIONS AND CORRECT ANSWERS To test for an obstructed flue pipe on an induced draft furnace , a technician should use ; - CORRECT ANSWER a manometer to test the negative pressure generated by the induced draft motor A gas furnace is to be installed in a garage . National standards require that the burners and ignition sources must be located above the floor ; - CORRECT ANSWER 18 inches 3 . Redundant gas valves used on gas furnaces have ; - CORRECT ANSWER shut off . B. no manual gas Burning one cubic foot of liquified petroleum ( LP ) gas completely will produce approximately ; - CORRECT ANSWER D. 2,000-2,500 Btu . Liquified petroleum ( LP ) gas has a specific gravity of ; - CORRECT ANSWER C. 1.5-2.0 . What is the purpose of using an adjustable shutter on older burners ? - CORRECT ANSWER Mix primary air and gas The primary function of the limit switch is to de - energize the ; - CORRECT ANSWER valve if the furnace overheats . C. gas A technician is using an extension ladder to work on a roof top unit . The top of the ladder should extend beyond the support point by ; - CORRECT ANSWER C. 3 feet . A technician determines that a natural gas furnace has a defective heat exchanger , The technician should ; - CORRECT ANSWER Inform the homeowner and turn off the gas supply to the furnace

Content preview

HVAC Gas Heat Exam UPDATED
ACTUAL QUESTIONS AND CORRECT
ANSWERS
To test for an obstructed flue pipe on an induced draft furnace , a technician should use ; - CORRECT
ANSWER a manometer to test the negative pressure generated by the induced draft motor



A gas furnace is to be installed in a garage . National standards require that the burners and ignition
sources must be located above the floor ; - CORRECT ANSWER 18 inches



3 . Redundant gas valves used on gas furnaces have ; - CORRECT ANSWER B. no manual gas
shut off .



Burning one cubic foot of liquified petroleum ( LP ) gas completely will produce approximately ; -
CORRECT ANSWER D. 2,000-2,500 Btu .



Liquified petroleum ( LP ) gas has a specific gravity of ; - CORRECT ANSWER C. 1.5-2.0 .



What is the purpose of using an adjustable shutter on older burners ? - CORRECT ANSWER
Mix primary air and gas



The primary function of the limit switch is to de - energize the ; - CORRECT ANSWER C. gas
valve if the furnace overheats .



A technician is using an extension ladder to work on a roof top unit . The top of the ladder should
extend beyond the support point by ; - CORRECT ANSWER C. 3 feet .



A technician determines that a natural gas furnace has a defective heat exchanger , The technician
should ; - CORRECT ANSWER Inform the homeowner and turn off the gas supply to the
furnace



The gas pressure usually required at the manifold and burners in a natural gas furnace is ; -
CORRECT ANSWER 3.5 inches WC

, The National Fuel Gas Code classifies a vent system for a condensing furnace as ; - CORRECT
ANSWER D. Category IV



The minimum distance Type - B vent pipe must be kept from combustible materials is ; - CORRECT
ANSWER D. one inch .



Typical condensing furnaces have an efficiency rating of at least ; - CORRECT ANSWER D.
90 % .



You have installed a Category IV , two - pipe vent system that terminates through the roof of the
residence . The elbow for the combustion air intake , above the roof , should ; - CORRECT ANSWER
point down .



The reason heating thermostats have anticipators or cycle rate adjustment is to - CORRECT
ANSWER reduce temperature swing .



Higher system efficiency is achieved in a category IV condensing furnace when the water vapor in the
flue gas condenses and releases ; - CORRECT ANSWER dioxide latent heat .



Natural gas consists primarily of ; - CORRECT ANSWER B. methane .



Burning one cubic foot of natural gas will produce approximately ; . - CORRECT ANSWER
900-1,100 Btu .



A furnace nameplate specifies a temperature rise of 40 to 70 degrees . Temperature measurements .
indicate a rise of 80 degrees . The most appropriate action is to ; - CORRECT ANSWER B.
increase fan speed .



A Btu is the amount of heat required to raise the temperature of one pound of water ; - CORRECT
ANSWER one - degree Fahrenheit .



Pressure drop in a natural gas piping system primarily occurs due to ; - CORRECT ANSWER
friction or resistance caused by the pipe and fittings installed in the piping system

Document information

Uploaded on
July 20, 2026
Number of pages
10
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
64
Followers
2
Items
9017
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions