CRAT CORE EXAM SETS 2026/2027 QUESTIONS AND
SOLUTIONS RATED A+
✔✔Digital Monitoring - ✔✔Transmitted over a computer where report is verified by a
licensed practitioner

✔✔Telemedicine monitoring is usually used to evaluate_____________ - ✔✔Artificial
Pacemaker Functioning

✔✔Ambulatory Monitor - ✔✔Most common type is holter monitor (continuous or
intermittent-only records when patient has symptoms. Used for dysrhythmias,
evaluation cardic meds, and checking pacemakers-24-48 hrs-up to 30 days

✔✔Procedure for applying ambulatory monitor (holter) - ✔✔Educate patient, equipment
gathered and prepared, electrodes placed on chest, equipment hooked up

✔✔Procedure for removing - ✔✔before removing, diary must be complete by patient,
then turn off recording, remove electrodes, clean skin, report results
*process is based on type of equipment uses

✔✔Functions of common ECG machine - ✔✔3 basic functions are input, signal
processing, output display. Sensors in ECG machine serve as receiving devices for the
electrical activity of the heart.
INPUT-Electrode placed on patients skin direct impulses to ECG instrument, providing
the input. Signal processing happens in ECG machine, output display is the result of
processing and is shown on screen (known as oscilloscope) and/or on ECG tracings.
Electronic output is quickly becoming most common choice for ECG tracings.

✔✔ECG machine controls - ✔✔# most common are speed, gain, artifact filter.
also have these controls: LCD display, heart rate limits, standardization, and lead
section

✔✔Speed control - ✔✔regulates how fast or slow the paper or data run during
procedure. MOST COMMONLY USED: 25 mm/sec
*increasing the speed for example to 50mm/sec will make wave forms appear wider and
is useful if patient heart rate is very fast. if you change the speed you must note on
tracing by circling the setting on tracing and notify the healthcare provider
*speed in measure on a horizontial axis

✔✔Gain - ✔✔control on ECG machine that increases or decreases size of ECG tracing.
Normal setting is 10mm/mV. 20mm/V will double size and 5mm/V will reduce size by
half
* NEED TO KNOW mV is a millivolt-unit of measurement to indicate voltage- Voltage is
measures on a vertical axis

, ✔✔Artifact Filter - ✔✔unwanted marks on ECG tracing caused by something other than
heart activity
*Normal settings is between 40-150Hz, 40 Hz can be used to reduce artifact

✔✔3 most common causes of artifact are: - ✔✔Somatic tremor, wandering baseline,
and AC interference

✔✔History of ECG - ✔✔1903-Wilhelm Einthoven

✔✔ECG graph paper - ✔✔Boxes are 5mm by 5mm and indicate .04 seconds in time
horizontally and .1 mV in voltage vertically

✔✔How many seconds are between 3 tick marks on top of ecg paper? - ✔✔6 seconds

✔✔EGC PAPER provides measurement for both______ - ✔✔time and voltage.
smallest box =.04 second in time and 1mm or .1mV in voltage
2 large boxes =10mm, which equals 1cm for vertical measurement.

✔✔ECG machines must be calibrated - ✔✔so that 1cm=1mV

✔✔Center for disease control & Prevention has 2 levels of precautions which
are_________ - ✔✔1. Standard-Hand Hygiene/gloves for blood/body fluids, non-intact
skin, and mucous membranes. For standard wash hands and use gloves
2.Isolation precautions-airborne, droplet, contact For Isolation wash hands, use gloves,
and use personal protective equipment

✔✔Ethics - ✔✔standards of behavior/right vs wrong

✔✔Laws - ✔✔established by government
Illegal acts are always unethical but unethical acts are not always illegal Chapter 1

✔✔HIPPA - ✔✔Health Insurance Portability and Accountability Act
established in response to information being transmitted electronically Established 1996
past into law 2003. Patient info can only be shared for patients care. This includes
patient address and phone number. Fines if violate law.

✔✔For HIPPA questions keep in mind: - ✔✔HIPPA was enacted to protect the patient,
you need two forms of identification to be sure you have right patient, you need an order
to do test, connect supervisor or follow organization's procedure are usually correct
ansers.

✔✔Age to have a routine ECG - ✔✔40

Document information

Uploaded on
July 19, 2026
Number of pages
6
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK
3.5
(41)
Sold
283
Followers
10
Items
32850
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions