This document provides a comprehensive practice review for the EPA Section 608 Type II Certification Examination for the 2026/2027 certification cycle. It includes 25 practice questions with correct answers covering refrigerant recovery, high-pressure appliances, leak detection requirements, evacuation procedures, refrigerant handling, safety protocols, and EPA Section 608 regulatory compliance. The content emphasizes environmentally responsible refrigerant management, proper servicing procedures, technician safety, and federal regulatory requirements applicable to high-pressure HVAC/R systems. This resource is designed to strengthen HVAC/R technical competency and support preparation for the EPA Section 608 Type II certification examination.

Content preview

EPA 608 TYPE 2 CERTIFICATION EXAM
2026-2027 | (25 QUESTIONS AND
CORRECT ANSWERS) | ALREADY
GRADED A+ | 100% VERIFIED
HVAC/R & Environmental Compliance | EPA | Key Domains: Refrigerant Recovery, High-
Pressure Systems, Leak Detection, Evacuation Procedures, Safety Protocols, and EPA Section
608 Regulations | Expert-Aligned Structure | Exam-Ready Format



Introduction
This structured EPA 608 Type 2 Certification Exam for 2026-2027 provides 25 high-quality
exam-style questions with correct answers and rationales. It emphasizes refrigerant
handling, high-pressure system maintenance, leak detection, and environmental safety
protocols critical to professional HVAC/R practice and successful EPA Section 608
certification under 40 CFR Part 82 Subpart F and AIM Act Subpart C (ER&R Program,
effective Jan 1, 2026). Type II covers high-pressure and very high-pressure appliances:
refrigerants with liquid-phase saturation pressure between 170-355 psia and above 355
psia at 104F, including R-22, R-407C, R-404A, R-507, R-410A, R-32, R-454B, R-452B.

Answer Format
All correct answers appear in bold and cyan, accompanied by concise rationales explaining
safety/operational reasoning, code adherence, and why alternative options are less
appropriate.

Regulatory Update & Passing Score - 2026-2027
Official Proctored Type II Exam: 25 questions, 70% required to pass = 18 correct answers (72%). The
21/25 (84%) threshold applies ONLY to Type I open-book mail-in format. This document contains
exactly 25 exam-accurate questions aligning with authentic body-administered Type II length.
Current leak thresholds (per 2016 Rule and AIM Act ER&R Final Rule 2024, compliance Jan 1, 2026):
Comfort Cooling 10%, Commercial Refrigeration 20%, Industrial Process Refrigeration 30% per year,
applicable to 50+ lbs ODS and 15+ lbs HFC or substitute with GWP >53. Required evacuation per
EPA.gov table Sept 8, 2025: Very high-pressure 0 in Hg, High-pressure less than 200 lbs 0 in Hg, High-
pressure 200+ lbs 10 in Hg vacuum post-1993 equipment. Fines up to $44,539 per day per violation.

, Question 1:

Which definition best describes a high-pressure appliance under EPA Section 608?

A. An appliance that uses a refrigerant with liquid-phase saturation pressure below 45
psia at 104F

B. An appliance that uses a refrigerant with liquid-phase saturation pressure between
170 psia and 355 psia at 104F

C. An appliance that uses a refrigerant with liquid-phase saturation pressure between
45 psia and 170 psia at 104F

D. A small appliance manufactured, charged and hermetically sealed with 5 lbs or less of
refrigerant

Correct Answer: B. An appliance that uses a refrigerant with liquid-phase saturation
pressure between 170 psia and 355 psia at 104F

Rationale: EPA categorizes by saturation pressure at 104F per 40 CFR 82.152. Below 45 =
low-pressure Type III (R-123), 45-170 = medium-pressure (R-134a, R-12), 170-355 = high-
pressure (R-22, R-407C, R-410A, R-404A), above 355 = very high-pressure (R-13, R-23).
Option A is low-pressure, C is medium-pressure, D is Type I.



Question 2:

Which of the following refrigerants is classified as a high-pressure refrigerant covered
under EPA 608 Type II?

A. R-11

B. R-123

C. R-410A and R-22

D. R-600a isobutane

Correct Answer: C. R-410A and R-22

Rationale: Type II includes high and very high-pressure appliances such as R-22 HCFC, R-
407C, R-404A, R-507, R-410A, R-32, R-454B. R-11 and R-123 are low-pressure chillers Type
III. R-600a is hydrocarbon in domestic small appliances. EPA clarified R-410A is high-
pressure not very high-pressure as of current guidance.



Question 3:

Document information

Uploaded on
July 18, 2026
Number of pages
14
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorAgness
3.8
(6)
Sold
51
Followers
5
Items
1463
Last sold
14 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions