NFPA-99 2026. Practice Test Questions
(With Ref.)

**Under which of these conditions shall the instrument Air Reserve header cylinders be
permitted to be stored with the instrument air compressor?
A) the mechanical equipment room does not contain a boiler.
B) the medical air compressors are in the same room.
C) the only motor-driven machinery in the room is for instrument air equipment.
D) the room is secured with lockable doors. - answerC) The only motor-driven
machinery in the room is for the instrument air equipment

Riser valves are those valves located where?
A) adjacent to the main riser downstream of any zone valve.
B) anywhere in the lateral branches of the piping system.
C) in the mainline adjacent to the base of the riser.
D) in the riser adjacent to the mainline. - answerD) In the riser adjacent to the main line
{5.1.4.4}

When is the initial pressure test conducted by the installer?
A) after blowdown of the distribution piping.
B) after installation of alarm sensors.
C) before blowdown of distribution piping.
D) before installation of station rough in assembly. - answerA) After blow-down of the
distribution piping.{5.1.12.2.3.2(1)}

**In those portions of systems intended to handle oxygen at pressure greater than 350
psi the inter connecting hose shall not contain what materials?
A) brass.
B) copper
C) polymeric
D) stainless steel - answerC) Polymeric

The tool shown here allows the installer to mechanically limit the makeup depth of the
fitting to be brazed. Under what condition is this method permitted for the installation of
medical gas piping?
A) only on final line connectors.
B) only on vacuum systems.
C) where only B cup 5 brazing rod is used
D) where the limited makeup depth is not less than minimum cut depth her ANSI /
ASME recommendations - answerD) Where the limited makeup depth is not less than
minimum cup depth current ANSI\ASME recommendation {5.1.10.4.6.1}

,What is the standard gauge pressure for nitrogen gas service?
A) 15 - 30
B) 50 - 55
C) 162 185
D) it varies with system type. - answerC) 160 - 185psi {5.1.11}

What is a NFPA 99 requirement for labeling of pipes in medical gas system?
A) color coding
B) fixed label width
C) label shall wrap completely around pipe.
D) reflective label - answerA) Color coding {5.1.11.1(1)}

A wireless communication device is employed in a medical gas or vacuum warning
system. what type of supervision is required for this device?
A) a visual indicator Shelby located in maintenance officer or engineering department.
B) this device shall be installed at the medical gas or vacuum source.
C) this device shall be located at nurses station.
D) this device will be supervised such that failure communication shall initiate an alarm.
- answerD) This device will be supervised such that failure of communication shall
initiate an alarm {5.1.9.1 (12)}

In a facility where Medical Gas vacuum systems are present and the failure of such
equipment or systems is likely to cause any major injury or death to patients or
caregivers this system shall be designed to meet which category requirements?
A) 1
B) 2
C) 3
D) 4 - answerA) category 1 {5.1.1.2(2) or 4.1.1}

A faculty is in the planning stages of installing an emergency oxygen service connection
(ESOC). How many feet is the minimum amount of clearance required around this
connection?
A) 1 foot
B) 3 feet
C) 5 feet
D) Clearance must be 1-1/2 times the width of the auxiliary. - answerB) 3 feet
{5.1.3.5.15.2(7)}

Wooden rack for cylinder storage may be permitted under which conditions?
A) the wooden must be painted.
B) they are permitted with no set conditions .
C) they must be located in an area with fire suppression system.
D) Wooden racks are no longer permitted - answerD) Wooden racks are no longer
permitted {5.1.3.3.2(11)}

, If nonmetallic flexible connectors is being used in a category 1 healthcare faculty to
connect to the manifold to the gas distribution piping what is the maximum length
permitted for the flexible connectors?
A) 2.5 feet
B) 5 feet
C) They shall be no longer necessary
D) the use of flexible connectors is not permitted. - answerC) They shall be no longer
necessary {5.1.10.11.6}

What type of copper tube hanger shall be used for potentially damp locations?
A) carbon steel
B) copper coated
C) Plastic coated or insulated with material that will be non-absorbent or
D) solid copper - answerC) Plastic coated or insulated with material that will be non-
absorbent {5.1.10.11.4.4}

A patient care room is any room of health care faculty where in patients are being
intended to be?
A) either admitted or discharged
B) Examined or treated
C) interviewed
D) sent for x-rays - answerB) Examined or treated {3.3.127}

Oxygen cylinders in use and storage shall be prevented from reaching temperatures in
excessive how many degrees Fahrenheit?
A) 100
B) 125
C) 155
D) 180 - answerB) 125 degrees {5.1.3.2.12}

Liquid containers shall have additional product identification such as 360 degree wrap
around tape for medical liquid containers visible from all directions within a minimum of
blank high letters?
A) 1 inch
B) 2 inch
C) 3 inch
D) 4 inch - answerB) 2 inches {5.1.3.1.3}

**What is the systems that shall not be permitted to be located in an outdoor enclosure?
A) Bulk cryogenic liquid system
B) manifolds for cryogenic liquid cylinders
C) manifolds for gas cylinders, without a reserve
D) med air compressor supply source - answerA) Bulk cryogenic liquid system

Written for

Institution
NFPA 99
Course
NFPA 99

Document information

Uploaded on
July 18, 2026
Number of pages
16
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$17.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
NFPA 99 EXAM BUNDLED
-
12 2026
$ 91.74 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Resolution Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
311
Member since
3 year
Number of followers
188
Documents
16066
Last sold
1 day ago
NURSING VIEW

In my shop you will find documents, package deals, nursing courses, assigments,flashcards and all revision materials .You are welcome

4.0

61 reviews

5
38
4
4
3
6
2
4
1
9

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions