NFPA 99 2026 Worksheet 10

After a final tie in on an active vacuum system, each vacuum joint shall be tested with a
BLANK leak detector or other means that will allow detectant on an active vacuum
system - answer Ultrasonic

After the final tie in each joint shall be leak tested by the source gas. New work and the
existing system at the normal operating pressure shall be leak checked with a leak
detectant that is safe for use with oxygen and does not contain - answer Ammonia

After the piping system, the blow down test shall be done. Then the installer must
perform which test? - answer Initial pressure test

Alarm panels and shutoff valves labeling shall be ____________ when modifications
are made, changing the areas serviced - answer Updated

Area alarms shall be tested to verify the warning signals for all vital life support and
critical care areas if the pressure in the piping system increases or decreases by
BLANK - answer20%

At the sample port a demand of approximated 25% load shall be created to cause the
compressors to cycle on and off continuously and the dryers to operate for the ______
period. - answer12 hour

Before the piping system is put into use, who is responsible for the ascertaining that the
gas delivered to the outlet/inlet has the proper labels and connecting fittings. -
answerFacility Authority

Breached portions of the systems subject to inspection and testing shall be confined to
only the specific altered zone or area that is downstream for pressure gases at the point
of intrusion. Where a system shall be declared breached? - answerPhysical separation
of pipeline
System component removal
Replacement or addition of system components

Category 1 facility, testing, and calibration procedures shall be established to ensure
carbon monoxide monitors are calibrated __________. - answerAnnually or more often,
if recommended by the manufacturer

Category 2 & 3 medical gas systems are required to have how many alarm panels? -
answer1

Document information

Uploaded on
July 18, 2026
Number of pages
3
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Resolution
4.0
(61)
Sold
313
Followers
188
Items
16070
Last sold
3 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions