MED GAS NFPA WORKSHEET #3

Inlet filtration of the medical-surgical vacuum central supply systems shall contain all
except which of the following essentials? - answer filtration shall be sized a minimum of
50% of peak demand

vacuum piping for _____ shall be connected separately from the medical surgical
system directly to the receiver tank through its own isolation valve and fluid trap located
at the receiver - answer a teaching laboratory

which of these is an acceptable location for the exhaust of medical vacuum? -
answeraway from public places

where WAGD is produced by the medical surgical vacuum source, the total
concentration of oxidizers shall be maintained below _____ percent - answer23.6 %

which source shall NOT be used to power the venturi for the WAGD system -
answermedical air

oxygen central supply systems with an oxygen concentrator, having three supply
sources, shall NOT be allowed if: - answera documented risk analysis has NOT been
completed

except for zone and future valves, all valves shall be located in secured areas such as
locked pipe chases or be: - answerlocked or latched in their operating posititon

with the approval of the authority having jurisdiction, in which areas shall the shutoff
valves be permitted to be secured to prevent inappropriate access? - answerpediatric

what is the minimum flow coefficient (Cv) different allowed between inlet side and outlet
side of a full open 1-inch positive pressure valve? - answer60

where multiple freestanding buildings are being served by one central supply source,
what minimum number of main line shutoff valves is required? - answerone for each
building

riser valves are located where? - answerin the riser adjacent to the main line

which of the following is a requirement for the configuration of a zone valve box? -
answerplaced such that a wall intervenes between the inlets/outlets they control

zone valves are NOT permitted to be installed in which of these locations? - answerin
the same room as the outlets/inlets that it serves

Document information

Uploaded on
July 17, 2026
Number of pages
3
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Resolution
4.0
(61)
Sold
313
Followers
188
Items
16070
Last sold
3 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions