ICC Masonry Comprehensive Resource To Help You Ace Exams Includes Frequently Tested Questions With ELABORATED 100% Correct COMPLETE SOLUTIONS Guaranteed Pass First Attempt!! Current Update!! 1. Windbreaks shall be used when the temp is below 25°F and the wind is ..... A. 8 mph or more B. 10 mph or more C. 12 mph or more D. Greater than 15 mph - Correct Answer: Answer D. Greater than 15 mph 2. After the initial water has been introduced to the mix, mortar should be used within ..... A. 30 minutes B. 1 hour C. 1-1/2 hour D. 2-1/2 hour - Correct Answer: Answer D. 2-1/2 hour 3. A common CMU size is 6" x 8" x 16". The 8" refers to the ..... A. Width B. Height C. Length - Correct Answer: Answer. B. Height 4. During hot weather conditions, newly constructed masonry shall be fog sprayed until damp at least ..... times a day for ..... days A. Twice a day for 3 days B. Twice a day for 5 days C. 3 times a day for 3 days D. 3 times a day for 5 days - Correct Answer: Answer C. 3 times a day for 3 days 5. When associated with masonry reinforcing steel, the "d" distance is defined as the distance from ..... to the center of the reinforcing steel. A. The inside of the face shell B. The nearest reinforcing bar C. The farthest face of the CMU D. The centerline of an associated lap splice bar - Answer C. The farthest face of the CMU 6. When performing the Cone Penetrometer Test, the depth of penetration is measured in ..... A. Meters B. Millimeters C. Centimeters D. Inches - Correct Answer: Answer B. Millimeters 7. The recommended slump is necessary so that grout can flow ..... A. Without hydration B. Completely surround the steel C. Into the cracks D. Without hydrostatic pressure - Correct Answer: Answer B. Completely surround the steel 8. Maximum horizontal spacing of control joints should be ..... A. 45 to 60 feet B. 30 to 45 feet C. 25 to 30 feet D. 20 to 30 feet - Correct Answer: Answer C. 25 to 30 feet 9. When high lift grouting, the full height of any section of wall should be completed in one day, with no interruption between lifts greater than ..... A. One hour B. Two hours C. Three hours D. Four hours - Correct Answer: Answer A. One hour Expansion joints are used to provide for movement of a wall as it expands and must contain incompressible material. 10. True or False - Correct Answer: Answer is False

Content preview

ICC Masonry

Comprehensive Resource To Help You Ace 2026-2027 Exams
Includes Frequently Tested Questions With ELABORATED
100% Correct COMPLETE SOLUTIONS

Guaranteed Pass First Attempt!! Current Update!!



1. Windbreaks shall be used when the temp is below 25°F and the wind is .....
A. 8 mph or more
B. 10 mph or more
C. 12 mph or more
D. Greater than 15 mph - Correct Answer: Answer D. Greater than
15 mph


2. After the initial water has been introduced to the mix, mortar should be
used within .....
A. 30 minutes
B. 1 hour
C. 1-1/2 hour
D. 2-1/2 hour - Correct Answer: Answer D. 2-1/2 hour


3. A common CMU size is 6" x 8" x 16". The 8" refers to the .....
A. Width
B. Height
C. Length - Correct Answer: Answer. B. Height

,4. During hot weather conditions, newly constructed masonry shall be fog
sprayed until damp at least ..... times a day for ..... days
A. Twice a day for 3 days
B. Twice a day for 5 days
C. 3 times a day for 3 days
D. 3 times a day for 5 days - Correct Answer: Answer C. 3 times a day
for 3 days


5. When associated with masonry reinforcing steel, the "d" distance is defined
as the distance from ..... to the center of the reinforcing steel.
A. The inside of the face shell
B. The nearest reinforcing bar
C. The farthest face of the CMU
D. The centerline of an associated lap splice bar - Correct Answer:
Answer C. The farthest face of the CMU


6. When performing the Cone Penetrometer Test, the depth of penetration is
measured in .....
A. Meters
B. Millimeters
C. Centimeters
D. Inches - Correct Answer: Answer B. Millimeters


7. The recommended slump is necessary so that grout can flow .....
A. Without hydration
B. Completely surround the steel
C. Into the cracks
D. Without hydrostatic pressure - Correct Answer: Answer B.
Completely surround the steel

, 8. Maximum horizontal spacing of control joints should be .....
A. 45 to 60 feet
B. 30 to 45 feet
C. 25 to 30 feet
D. 20 to 30 feet - Correct Answer: Answer C. 25 to 30 feet


9. When high lift grouting, the full height of any section of wall should be
completed in one day, with no interruption between lifts greater than .....


A. One hour
B. Two hours
C. Three hours
D. Four hours - Correct Answer: Answer A. One hour


Expansion joints are used to provide for movement of a wall as it expands
and must contain incompressible material.



10.True or False - Correct Answer: Answer is False


11.Mortar projections in grout cells must not project more than ..... into a cell.
A. 0 inches
B. 1/4 inches
C. 1/2 inches
D. 1 inch - Correct Answer: Answer C. 1/2 inches

Document information

Uploaded on
July 12, 2026
Number of pages
26
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EWLindy
3.7
(114)
Sold
768
Followers
432
Items
8537
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions