2026 CLTM CORRECT EXAMS TEST PAPER
QUESTIONS AND ANSWERS SURE A+
✔✔An electrode application technique considered the only method that will insure a
stable long term scalp recording is: - ✔✔Collodion

✔✔Which electrodes are MRI conditional for intracranial monitoring? - ✔✔Platinum

✔✔For stimulation of median nerve somatosensory evoked potentials, utilizing a pair of
stimulating electrodes the cathode is placed: - ✔✔Proximal

✔✔What type of material is favored for Stereo EEG electrodes due to its MRI
compatible properties? - ✔✔Nickel-Cromium composite

✔✔Strip and grid electrodes are composed of: - ✔✔Stainless steel or platinum

✔✔Strip and grid electrodes contacts are typically separated by inter-electrode
distances of: - ✔✔0.5 cm to 1 cm

✔✔In the 10-20 international electrode system, which electrode is placed halfway
between Fp2 and O2 when measuring the circumference? - ✔✔T8

,✔✔The most feared complication of intracranial electrode placement - ✔✔Hemorrhage

✔✔Per ACNS guidelines, what is the m minimum number of EEG channels required for
LTME equipment capability? - ✔✔32-64 channels

✔✔According to the international League Against Epilepsy (ILAE) 2015 guidelines for
Status Epilepticus (SE) SE can result in neuronal injury and function deficits are likely
after: - ✔✔30 Minutes

✔✔**ACNS Guidelines recommends that the reference electrode for localization of
sensorimotor cortex should be placed - ✔✔Contralateral scalp or ear

✔✔Per ACNS guidelines, LTME equipment must be able to record video for a minimum
of: - ✔✔24 hours

✔✔ACNS guidelines recommends the following filter performance specifications: -
✔✔LFF? 1 Hz- HFF 70 HZ

✔✔PEr ACNS guidelines, an important aspect of montage design for LTME is to clearly
separate activity from the: - ✔✔Basal temporal and 10/20 cortical derivations

✔✔ACNS Guidelines recommends the following filter performance specifications -
✔✔LFF 0.5 Hz- HFF 70 Hz

✔✔According to the international League Against Epilepsy (ILAE) 2015 Guidelines for
Status Epilepticus (SE), SE treatment should begin after - ✔✔5 minutes

✔✔Digital long term monitoring equipment must be able to record for a minimum of how
many hours? - ✔✔24

✔✔Crossing of cables is a troubleshooting technique that helps to eliminate what? -
✔✔50-60 Hz interference

✔✔During functional mapping, afterdischarges (AD) are more likely to occur with
intensity greater than: - ✔✔10mA

✔✔What condition does ACNS NOT recommend long term monitoring for neonates? -
✔✔autonomic paroxysms

✔✔In 58% of neonatal seizures, electro clinical uncoupling occurs after antiseizure
medication is given, what would you expect to see on a VEEG? - ✔✔Subclinical seizure
continue

, ✔✔How would you term: generalized rhythmic delta activity + sharp waves, according to
the 2012 ACNS EEG terminology? - ✔✔GRDA+S

✔✔How many channels are required to provide basic characterization of epileptic EEG
events? - ✔✔16

✔✔Monitoring for epilepsy. SI refers to EEG activity that is: - ✔✔stimulus induced

✔✔Which neonatal population would be a good candidate for long term monitoring? -
✔✔patients that are high risk for acute brain injury

✔✔What does LPD+R stand for in the 2012 ACNS EEG terminology - ✔✔lateralized
periodic discharges + superimposed rhythmic activity

✔✔What is the best high frequency filter setting during invasive EEG monitoring -
✔✔150 Hz

✔✔**LPDs is the new terminology for what EEG term - ✔✔PLEDS

✔✔Checking the impedance of intracranial electrodes poses a risk to a patient because:
- ✔✔alternating current is passed through the electrodes

✔✔Per ACNS guidelines, epidural, subdural, intracerebral, forâmen ovale- impedance
measurements can be safely performed with currents in the range of: - ✔✔10nA

✔✔Impedance measurements can be safely performed in intracranial electrodes only if:
- ✔✔performed with low currents in the range of 10nA

✔✔Continuous EEG is more sensitive for seizure detection than routine EEG in which
population of patients? - ✔✔Infants

✔✔A typical surgical treatment that is considered for Temporal Love Epilepsy -
✔✔Focal resection

✔✔Seizures characterized by hyper salivation, oral-facial apraxia, and at times facial
clinic activity, originate: - ✔✔Frontal operculum

✔✔Electrical Status Epilepticus in Sleep (ESES) is linked to: - ✔✔Landau-Kleffner
syndrome

✔✔What EEG pattern is a result of the treatment of status epilepticus - ✔✔Burst
Suppression

Document information

Uploaded on
July 11, 2026
Number of pages
19
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXAMCAFE
3.4
(19)
Sold
153
Followers
7
Items
26057
Last sold
21 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions