CT basics - CORRECT ANSWER=·Essentially an x-ray tube that rotates round the pt




20
·Table moves, feeding pt into the gantry

·Each large is data collected as a series of slices

am
o Each slice is divided into voxels (volume elements)
Each sweep of the source-detector around the body during CT is called a
. - CORRECT ANSWER=translation
Ex

Each CT projection records variations in
.- CORRECT ANSWER=mass density and effective atomic number
s
rt



Each CT projection is .
pe




1. printed on film

2. stored on the computer
Ex




3. displayed on the monitor - CORRECT ANSWER=stored on the computer



The cross-sectional anatomy is translated into
during CT reconstruction. - CORRECT ANSWER=amatrix of values

,The first generation of computed tomography used detector (s). - CORRECT
ANSWER=one




The principal drawback of the first-generation CT scanner was the .- CORRECT
ANSWER=long scanning time




6
What is windowing? - CORRECT ANSWER=Amethod in which the CT image gray scale can be




2
manipulated in order to enhance different structures of varying tissues




20
What are the 2 windowing mechanisms? - CORRECT ANSWER=- Window width

- Window level
am
What is Window Width (WW)? - CORRECT ANSWER=- The range of the CT numbers in the image
Ex
- Determines the maximum number of shades of gray that can be displayed on the CT monitor

- Effects contrast
ts


What is Window Level (WL)? - CORRECT ANSWER=- The center or midpoint of the range of CT
r



numbers
pe




- Effects brightness
Ex




Wide window widths (400 to 2000 HU) are necessary for ?- CORRECT
ANSWER=Varying body tissues



Narrow window widths (50 to 350 HU) are necessary for ? - CORRECT
ANSWER=Different tissues of similar densities

,What are the effects of WW on image contrast? - CORRECT ANSWER=- As the WW
increases, the contrast decreases

- As the WW decreases, the contrast increases




26
What are the effects of WL on image brightness? - CORRECT ANSWER=- Moving the WL
toward the higher CT numbers results in a darker image




20
- Moving the WL toward the lower CT numbers results in a brighter image



am
What is a multi-slice scanner (MSCT)? - CORRECT ANSWER=- CTsystem equipped with a
multiple-row detector array to simultaneously collect data at different slice locations

- Can scan up to 64 slices
Ex

In CT, the attenuated image-forming radiation is detected by what? - CORRECT
ANSWER=A solid state image receptor
s
rt



What is Helical CT? - CORRECT ANSWER=- Continuous gantry rotation + continuous table
pe




feed

- Scan data traces a helical path or spiral around patient
Ex




What is Isotropic Imaging? -CORRECTANSWER=2Dpixel in a CT image represents a 3D voxel



Name the 3 types of Data acquisition systems? - CORRECT ANSWER=- Conventional

, - Helical single slice (spiral)

- Multi-slice



What is a Linear Attenuation coefficient? - CORRECT ANSWER=Characterizes how easily a volume of

material can be penetrated by the x-rays




2 6
20
What is a bowtie filter? - CORRECT ANSWER=Used to allow a uniform beam to reach detectors




What occurs with CT filtration? - CORRECT ANSWER=- Removes long wavelength x-rays which
contributes to patient dose am
- Shapes the energy distribution across the radiation beam to produce uniform beam hardening
when x-rays pass through the filter and the object causing beam hardening artifacts
Ex

What is pitch? What is the formula? - CORRECT ANSWER=Relationship between the patient couch
ts


movement and the x-ray beam collimation and is expressed as a ratio
r
pe




Pitch = Couch movement each 360 degrees / Slice Thickness



How do different structures appear on CT? - CORRECT ANSWER=- Bone and high density structures,
Ex




such as radiopaque contrast media, appear white

- Air and other low density structures appear black

- Fat and organs appear in varying shades of gray

Document information

Uploaded on
July 10, 2026
Number of pages
50
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$20.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Nursexperts
1.7
(3)
Sold
35
Followers
0
Items
1022
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions