Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 7 pages
Exam (elaborations)

Fresenius PCT Exam Study Guide Exam Latest 2026 Updated Questions and Verified 100% Solutions (2026/2027) |A+ Graded |Guaranteed Pass

Document preview thumbnail
Preview 2 out of 7 pages

Fresenius PCT Exam Study Guide Exam Latest 2026 Updated Questions and Verified 100% Solutions (2026/2027) |A+ Graded |Guaranteed Pass

Content preview

Fresenius PCT Exam Study Guide Exam Latest 2026 Updated
Questions and Verified 100% Solutions (2026/2027) |A+
Graded |Guaranteed Pass

Normal _____ is used to rinse and prime the tubing of the extracorporeal circuit to remove
sterilant and air. - Answer -saline




Why do you compare the machine conductivity setting to the meter conductivity results? -
Answer -to ensure the machine display is correct




Air is removed from the extracorporeal circuit before initiating treatment because it may cause
____ when trapped in the dialyzer. - Answer -clotting




The most likely cause of contamination of the extracorporeal circuit are ____ in the prime
bucket with ____ end caps. - Answer -bloodlines, open




A low-level arterial drip chamber can result in ____ entering the system causing an air embolism
or clotting. - Answer -air




____ is the ability of a substance to conduct an electrical charge. - Answer -conductivity




1|Page

, When blood escapes from the dialyzer blood compartment into the dialysate fluid
compartment, this is known as a ____. - Answer -blood leak




The final dialysate must have a pH between: ____ and ____. - Answer -6.9, 7.6




How often should the staff clean the dialysis machine with acid? - Answer -daily




When should alarm and pressure holding tests (PHT) should be performed on dialysis
machines? - Answer -before each treatment




What is removed by normal saline during then priming process? - Answer -air in the dialyzer




Before the start of treatment, check that the machine's conductivity alarm parameters are set at
____ of the machine's theoretical conductivity. - Answer -+/- 0.5mS




You should disinfect the dialysis machine with heat after doing what? - Answer -cleaning with
acid




In addition to safety checks, what tests must you perform to endure a safe patient treatment? -
Answer -meter conductivity and pH


2|Page

Document information

Uploaded on
June 30, 2026
Number of pages
7
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Examchemist
4.3
(3)
Sold
16
Followers
0
Items
3128
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions