1. A Colorado HVAC contractor is preparing to install a split air-
conditioning system in a residential home. Which of the following is
the MOST critical first step before beginning installation to ensure
compliance with professional standards and safety regulations?
A. Installing the refrigerant lineset immediately after unpacking equipment
B. Verifying system compatibility with existing electrical service and load
calculations
C. Charging the system with refrigerant to test compressor function
D. Running ductwork modifications without reviewing building plans
B
The most critical initial step is verifying system compatibility with the
existing electrical service and performing load calculations to ensure the
HVAC system is appropriately sized and safe. This prevents system failure,
inefficiency, and code violations before physical installation begins.
2. During refrigeration cycle operation, a technician observes that the
evaporator coil is freezing excessively. Which of the following is the
MOST likely cause?
,A. Excessively high refrigerant charge
B. Restricted airflow across the evaporator coil
C. Condenser fan operating at too high a speed
D. Oversized compressor capacity
B
Restricted airflow across the evaporator coil reduces heat absorption,
causing coil temperature to drop below freezing and resulting in ice
formation.
3. According to best practices in HVAC installation, what is the PRIMARY
reason for performing a pressure test on a refrigerant system before
charging it?
A. To ensure proper thermostat calibration
B. To verify duct leakage is within acceptable limits
C. To detect leaks and ensure system integrity under pressure
D. To measure compressor amperage draw
C
Pressure testing confirms that the system is leak-free and structurally
sound before refrigerant is introduced, preventing environmental hazards
and system inefficiency.
4. A technician is troubleshooting a furnace that repeatedly cycles on
and off in short intervals. Which condition is MOST likely responsible?
A. Oversized furnace relative to heat load
B. Undersized ductwork return system
C. Dirty condenser coil
D. High refrigerant subcooling
A
,Short cycling commonly occurs when the furnace is oversized, causing
rapid temperature rise and premature shutdown.
5. In HVAC systems, what is the PRIMARY function of the metering
device?
A. Compress refrigerant vapor into liquid
B. Control refrigerant flow into the evaporator
C. Remove moisture from refrigerant lines
D. Increase refrigerant pressure before condensation
B
The metering device regulates refrigerant flow into the evaporator to
maintain proper pressure and temperature conditions for heat absorption.
6. A Colorado HVAC contractor must ensure compliance with safety
standards when handling refrigerants. Which practice is REQUIRED
under environmental regulations?
A. Venting refrigerant during system repairs
B. Recovering refrigerant using approved recovery equipment
C. Mixing different refrigerant types to improve efficiency
D. Storing refrigerant cylinders horizontally at all times
B
Regulations require refrigerant recovery using approved equipment to
prevent environmental damage and ensure safe handling.
7. What is the PRIMARY purpose of a heat exchanger in a gas furnace?
A. To mix combustion gases with indoor air
B. To transfer heat from combustion gases to indoor air without mixing
them
C. To increase gas pressure before ignition
D. To cool exhaust gases before venting outdoors
, B
The heat exchanger transfers heat to indoor air while keeping combustion
gases separate, ensuring safe operation.
8. Which electrical component in an HVAC system is responsible for
starting and running a single-phase compressor motor?
A. Transformer
B. Capacitor
C. Relay switch
D. Thermistor
B
Capacitors provide the phase shift required to start and maintain
operation of single-phase compressor motors.
9. A technician notices high head pressure in a refrigeration system.
Which condition is MOST likely the cause?
A. Dirty condenser coil restricting heat rejection
B. Low refrigerant charge
C. Excessively low ambient temperature
D. Oversized evaporator coil
A
A dirty condenser coil restricts heat transfer, causing elevated head
pressure in the system.
10. What is the PRIMARY function of a thermostatic expansion valve
(TXV)?
A. Control compressor lubrication flow
B. Regulate refrigerant superheat at the evaporator outlet