SKILLCAT EPA 608 Exam with verified detailed answers || || || || || || ||
As technicians we must stay up to date on - ✔✔Federal state and local law
|| || || || || || || || || || || || || ||
For universal certification you will receive how many questions - ✔✔100
|| || || || || || || || || ||
What is passing grade for all epa certifications - ✔✔70%
|| || || || || || || || ||
True or false you must memorize all regulations because they will stay the same forever -
|| || || || || || || || || || || || || || || ||
✔✔False
Can chlorine from the environment come from natural resources such as volcanoes - ✔✔Yes
|| || || || || || || || || || || || ||
but they are not the primary source
|| || || || || || ||
True or false Ground level ozone is is what reflects and absorbs harmful uv rays from the
|| || || || || || || || || || || || || || || || ||
sun - ✔✔False || ||
In which way does ozone depletion affect humans - ✔✔Increased risk of skin cancer and
|| || || || || || || || || || || || || || ||
cataracts
Is there evidence that refrigerants are in the stratosphere - ✔✔Yes
|| || || || || || || || || ||
One molecule of chlorine can destroy how many molecules of ozone - ✔✔100,000
|| || || || || || || || || || || ||
Ozone has ____ oxygen atoms. - ✔✔3
|| || || || || ||
True or false the majority of the ozone is located in the troposphere - ✔✔False
|| || || || || || || || || || || || || ||
,2
How many molecules of ozone can three molecules of chlorine destroy - ✔✔300,000
|| || || || || || || || || || || ||
What is the major function of ozone in the stratosphere - ✔✔Absorb and reflect uv rays
|| || || || || || || || || || || || || || || ||
from the sun || ||
What is the primary source of Chlorine in the stratosphere - ✔✔Emissions of refrigerants by
|| || || || || || || || || || || || || ||
human like cfc and hcfc
|| || || || ||
What molecule destroys the ozone layer - ✔✔Chlorine
|| || || || || || ||
Which of the following are effects of the ozone layer depletion - ✔✔Decreasing crop yields
|| || || || || || || || || || || || || || ||
and threat to wild and marine life
|| || || || || ||
Who does ozone depletion affect - ✔✔People all over the world
|| || || || || || || || || ||
After refrigerant is phased out can equipment still contain refrigerant - ✔✔Yes
|| || || || || || || || || || ||
After refrigerant is phased out can technicians service equipment containing that refrigerant
|| || || || || || || || || || || ||
- ✔✔Yes
||
After being phased out, where can technicians obtain refrigerant to service equipment that
|| || || || || || || || || || || || ||
contains that refrigerant? - ✔✔From recovered or reclaimed refrigerant
|| || || || || || || ||
Can refrigerant be resold - ✔✔Yes, but only if it has been reclaimed to AHRI Standard 700
|| || || || || || || || || || || || || || || || ||
specifications
, 2
Equipment has to be certified to epa standards in order to recover which refrigerants -
|| || || || || || || || || || || || || || ||
✔✔Cfc hcfc hfc || ||
If you are selling r 22 refrigerant who can you sell to - ✔✔A technician or business with an
|| || || || || || || || || || || || || || || || || || ||
epa 608 ||
If you recover r 22 can you use the recovered refrigerant in another device owned by a
|| || || || || || || || || || || || || || || || ||
different person - ✔✔Yes but only if it is reclaimed and meets ahri 700 standards
|| || || || || || || || || || || || || ||
In the United States when we're all CFCs phased out - ✔✔1995
|| || || || || || || || || || ||
In the United States when we're r22 r124b phased out - ✔✔2020
|| || || || || || || || || || ||
In the United States when will all HCFCS be phased out - ✔✔2030
|| || || || || || || || || || || ||
What records should be kept for r22 - ✔✔Type of refrigerant, dates and quantity of
|| || || || || || || || || || || || || || ||
refrigerant
Section 608 of EPA Clean Air Act is - ✔✔Federal law
|| || || || || || || || || ||
State and local regulations - ✔✔Have to be followed with federal law and may be stricter
|| || || || || || || || || || || || || || ||
The venting prohibition requires that you recover affected refrigerant before - ✔✔Opening,
|| || || || || || || || || || || ||
servicing, disposing equipment || ||
Under section 608 regulations who is responsible for ensuring that all refrigerant is removed
|| || || || || || || || || || || || ||
before disposing of equipment that contains refrigerant - ✔✔final person in the disposal
|| || || || || || || || || || || || || ||
chain
SKILLCAT EPA 608 Exam with verified detailed answers || || || || || || ||
As technicians we must stay up to date on - ✔✔Federal state and local law
|| || || || || || || || || || || || || ||
For universal certification you will receive how many questions - ✔✔100
|| || || || || || || || || ||
What is passing grade for all epa certifications - ✔✔70%
|| || || || || || || || ||
True or false you must memorize all regulations because they will stay the same forever -
|| || || || || || || || || || || || || || || ||
✔✔False
Can chlorine from the environment come from natural resources such as volcanoes - ✔✔Yes
|| || || || || || || || || || || || ||
but they are not the primary source
|| || || || || || ||
True or false Ground level ozone is is what reflects and absorbs harmful uv rays from the
|| || || || || || || || || || || || || || || || ||
sun - ✔✔False || ||
In which way does ozone depletion affect humans - ✔✔Increased risk of skin cancer and
|| || || || || || || || || || || || || || ||
cataracts
Is there evidence that refrigerants are in the stratosphere - ✔✔Yes
|| || || || || || || || || ||
One molecule of chlorine can destroy how many molecules of ozone - ✔✔100,000
|| || || || || || || || || || || ||
Ozone has ____ oxygen atoms. - ✔✔3
|| || || || || ||
True or false the majority of the ozone is located in the troposphere - ✔✔False
|| || || || || || || || || || || || || ||
,2
How many molecules of ozone can three molecules of chlorine destroy - ✔✔300,000
|| || || || || || || || || || || ||
What is the major function of ozone in the stratosphere - ✔✔Absorb and reflect uv rays
|| || || || || || || || || || || || || || || ||
from the sun || ||
What is the primary source of Chlorine in the stratosphere - ✔✔Emissions of refrigerants by
|| || || || || || || || || || || || || ||
human like cfc and hcfc
|| || || || ||
What molecule destroys the ozone layer - ✔✔Chlorine
|| || || || || || ||
Which of the following are effects of the ozone layer depletion - ✔✔Decreasing crop yields
|| || || || || || || || || || || || || || ||
and threat to wild and marine life
|| || || || || ||
Who does ozone depletion affect - ✔✔People all over the world
|| || || || || || || || || ||
After refrigerant is phased out can equipment still contain refrigerant - ✔✔Yes
|| || || || || || || || || || ||
After refrigerant is phased out can technicians service equipment containing that refrigerant
|| || || || || || || || || || || ||
- ✔✔Yes
||
After being phased out, where can technicians obtain refrigerant to service equipment that
|| || || || || || || || || || || || ||
contains that refrigerant? - ✔✔From recovered or reclaimed refrigerant
|| || || || || || || ||
Can refrigerant be resold - ✔✔Yes, but only if it has been reclaimed to AHRI Standard 700
|| || || || || || || || || || || || || || || || ||
specifications
, 2
Equipment has to be certified to epa standards in order to recover which refrigerants -
|| || || || || || || || || || || || || || ||
✔✔Cfc hcfc hfc || ||
If you are selling r 22 refrigerant who can you sell to - ✔✔A technician or business with an
|| || || || || || || || || || || || || || || || || || ||
epa 608 ||
If you recover r 22 can you use the recovered refrigerant in another device owned by a
|| || || || || || || || || || || || || || || || ||
different person - ✔✔Yes but only if it is reclaimed and meets ahri 700 standards
|| || || || || || || || || || || || || ||
In the United States when we're all CFCs phased out - ✔✔1995
|| || || || || || || || || || ||
In the United States when we're r22 r124b phased out - ✔✔2020
|| || || || || || || || || || ||
In the United States when will all HCFCS be phased out - ✔✔2030
|| || || || || || || || || || || ||
What records should be kept for r22 - ✔✔Type of refrigerant, dates and quantity of
|| || || || || || || || || || || || || || ||
refrigerant
Section 608 of EPA Clean Air Act is - ✔✔Federal law
|| || || || || || || || || ||
State and local regulations - ✔✔Have to be followed with federal law and may be stricter
|| || || || || || || || || || || || || || ||
The venting prohibition requires that you recover affected refrigerant before - ✔✔Opening,
|| || || || || || || || || || || ||
servicing, disposing equipment || ||
Under section 608 regulations who is responsible for ensuring that all refrigerant is removed
|| || || || || || || || || || || || ||
before disposing of equipment that contains refrigerant - ✔✔final person in the disposal
|| || || || || || || || || || || || || ||
chain