2026/2027 ACCURATE QUESTIONS
WITH CORRECT DETAILED
SOLUTIONS ||
100% GUARANTEED PASS
<NEWEST VERSION>
1. Internal ____ is not required for dynamic type compressors.
seals
lubrication
pressure monitoring
corrosion monitoring
temperature monitoring - ANSWER ✔ b
2. Low pressure or high pressure are the two primary classifications of ____.
centrifugal pumps
sump pumps
boilers
draft fans
pressure controllers - ANSWER ✔ e
3. When mixed with an alkaline sample, phenolphthalein will turn ____.
red
orange
pink
blue
green - ANSWER ✔ c
4. Gas burners should be ____ to perform a thorough cleaning and inspection.
,inspected semi-annually
inspected weekly
inspected monthly
inspected daily
inspected annually - ANSWER ✔ e
5. With regards to lighting systems, the advantages of low voltage switching
include:
No conduit is required for the wiring
All of the above
Adjustments can be made relatively easily
The control of lights can be remote or local
Adjustments can be made with relatively low capital costs - ANSWER ✔ b
6. ____ are installed in applications where the capability for the rotor to reverse
rotational direction is desired (example: ships).
Reciprocating engines
Heat engine
Steam engines
Gasoline engines
Diesel engines - ANSWER ✔ c
7. The overspeed trip component is required to be tested ____ to ensure its
correct functioning.
annually
after the turbine has experienced and overspeed trip
before the turbine is placed in service
after the turbine is placed in service
weekly - ANSWER ✔ c
8. Increased temperature of the supplied cooling water can reduce the
effectiveness of the oil seal between the ___.
injection nozzle seals
injection pump walls
,piston rings and cylinder walls
filter media
carburetor walls - ANSWER ✔ c
9. Plants utilize natural gas or light hydrocarbons from the wells as ____ for
the processing plant.
feedstock
raw gas
sour gas
sweet gas
hydrocarbons - ANSWER ✔ a
10.____ is a ratio of the water vapor content of the mixture to the total air
content on a mass basis.
Relative density
Saturation
Osmosis
Entropy
Specific humidity - ANSWER ✔ e
11.Cutters, drill heads, and wire brushes are all ____ used to clean boiler tubes.
mechanical methods
power methods
practical methods
chemical methods
maintenance methods - ANSWER ✔ a
12.Indirect and direct lighting systems can be installed in a building to improve
upon the ___.
1. luminaires
2. dimmer switches
3. automatic switches
4. occupancy sensors
5. ambient lighting - ANSWER ✔ 5. ambient lighting
, 13.Glycol cooling/heating systems should have the inhibitor strength and freeze
point verified every ____.
1. year
2. 3 to 5 years
3. week
4. quarter
5. month - ANSWER ✔ 1. year
14.To prevent force being applied to the boilers safety valve the ____ is
independently supported.
1. supervisory valve
2. blowdown valve
3. anchor
4. fuel valve
5. safety valve discharge piping - ANSWER ✔ 5. safety valve discharge
piping
15.It is a Life Safety Code requirement that ____ be installed in all institutional
and educational occupancies.
1. automatic switches
2. occupancy sensors
3. dimmer switches
4. emergency exit lighting
5. direct lighting systems - ANSWER ✔ 4. emergency exit lighting
16.Frosting of the recovery coil makes it difficult for the ___ to achieve heat
recovery during cold ambient conditions.
1. humidifier heat recovery
2. humidistat heat recovery
3. dual duct heat recovery
4. runaround type heat recovery
5. four pipe heat recovery - ANSWER ✔ 4. runaround type heat recovery
17.A(n) _____ is approved by code to perform boiler safety valve adjustments.
1. 2nd Class Power Engineer
2. 1st Class Power Engineer
3. 3rd Class Power Engineer
4. 4th Class Power Engineer
5. ASME certified agency - ANSWER ✔ 5. ASME certified agency