Pass your TCEQ Class C Water Operator License Exam on the first try! This comprehensive guide features 200+ realistic practice questions with detailed rationales—covering treatment processes (coagulation, sedimentation, filtration, disinfection), state and federal regulations (SDWA, RTCR, SWTR), distribution system requirements, monitoring, safety, math calculations, and real-world scenario-based problems. Updated for 2026. Learn the "why" behind every answer, master TCEQ rules, and walk into your exam with confidence. Perfect for water treatment operators preparing for Texas licensure. Download now and succeed!

Content preview

Page 1 of 60



TCEQ CLASS C WATER LICENSE EXAM

|VERIFIED 150Qs&As|NEW

UPDATE|TCEQ EXAM PREP

2026|A+GRADE

1. What is the maximum contaminant level (MCL) for total

coliform bacteria in a public water system under TCEQ rules?

a) 5% of samples per month

b) 1 sample positive per month

c) 0% positive samples (for systems collecting ≥40

samples/month)

d) 10% positive samples

Answer: c) 0% positive samples (for systems collecting ≥40

samples/month)

Rationale: Under the Revised Total Coliform Rule (RTCR), any

,Page 2 of 60


system collecting ≥40 samples/month must have no more than

5% positive for total coliform. However, for Class C systems

(typically small plants), zero tolerance is the operational goal.

But by rule: ≥40 samples → ≤5% positive; <40 samples → no

more than 1 positive. The exam often tests the stricter "zero" for

routine compliance.




2. A water sample tests positive for E. coli. What is the

required action?

a) Collect a repeat sample within 24 hours

b) Issue a boil water notice within 24 hours

c) Collect 3 repeat samples within 24 hours and notify TCEQ

within 24 hours

d) Nothing, unless two consecutive positives occur

Answer: c) Collect 3 repeat samples within 24 hours and

notify TCEQ within 24 hours

,Page 3 of 60


Rationale: An E. coli positive is an acute violation. The system must

collect 3 repeat samples (same day as notification, ideally within

24 hours), notify TCEQ immediately, and inform the public via a

boil water notice.




3. Under the Surface Water Treatment Rules (SWTR), what is

the required log reduction for Giardia lamblia for a

conventional treatment plant?

a) 2-log (99%)

b) 3-log (99.9%)

c) 4-log (99.99%)

d) 6-log (99.9999%)

Answer: b) 3-log (99.9%)

Rationale: SWTR mandates 3-log removal/inactivation of

Giardia and 4-log for viruses. Conventional treatment

, Page 4 of 60


(coag/floc/sed/filt) typically achieves 2.5-log Giardia, so

disinfection must add the rest.




4. Which of the following is a Primary MCL violation?

a) Turbidity >0.3 NTU

b) Chlorine residual of 0.1 mg/L at the far end of the system

c) Arsenic at 0.012 mg/L

d) pH of 8.5

Answer: c) Arsenic at 0.012 mg/L

Rationale: Primary MCL for arsenic is 0.010 mg/L (10 ppb).

Exceeding that is a health-based violation. Turbidity (secondary),

low chlorine (treatment technique), pH (secondary) are not

primary.




5. How often must a Class C surface water plant operator

perform a visible inspection of the treatment facility?

Document information

Uploaded on
June 3, 2026
Number of pages
60
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$28.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PREPPERFECT
4.7
(3477)
Sold
462
Followers
60
Items
13991
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions