Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 3 out of 17 pages
Exam (elaborations)

Backflow Prevention Practice Exam – Questions and Correct Answers Study Guide|| LATEST UPDATE

Document preview thumbnail
Preview 3 out of 17 pages

Backflow Prevention Practice Exam – Questions and Correct Answers Study Guide|| LATEST UPDATE

Content preview

Backflow Prevention Practice Exam –
Questions and Correct Answers Study
Guide|| LATEST UPDATE

Containing a plumbing system from the public water supply requires backflow protection
at the _______?
A. Appliance or fixture
B. Building foundation
C. Irrigation system
D. Service Connection
E. Sprinkler riser -CORRECTANSWER Service Connection

Backflow preventer manufacturers recommend that assemblies be field-tested annually
and when_____?
A. Installed
B. Moved
C. Repaired or Installed
D. Shut down
E. Water suppliers provide notice -CORRECTANSWER Repaired or Installed

A differential pressure gauge reading of 0.2 psid is represented on water column sight
tube by _____?
A. 1/16 in. (0.16 cm)
B. 1/2 in. (1.3 cm)
C. 2 in. (5.1 cm)
D. 3.5 in. (8.9 cm)
E. 5.5 in. (14 cm) -CORRECTANSWER 5.5 in. (14 cm)

Pollution of a public water supply suggests the substance in the water is ____?
A. Aesthetically bad
B. Biological with virus only
C. Lowering the pH below 1.4
D. Radiological
E. Toxic -CORRECTANSWER Aesthetically bad

Backsiphonage may occur when the pressure inside copper tubing is ____?
A. Greater than atmospheric pressure
B. Greater than barometric pressure
C. Greater than 0 gauge pressure
D. Less than absolute pressure

,E. Less than atmospheric pressure -CORRECTANSWER Less than atmospheric
pressure

A cross-connection may be a permanent piping arrangement or a(n) ____?
A. Backflow preventer
B. Church symbol
C. OSHA hazardous area designation
D. Railroad and highway intersection sign
E. Temporary hose bibb connection -CORRECTANSWER Temporary hose bibb
connection

The isolation of a plumbing water system hazard requires____?
A. Appliance protection
B. Building quarantine
C. High-hazard protection
D. Meter protection
E. Toxin monitoring -CORRECTANSWER Appliance protection

A direct cross-connection suggests the piping system may be subjected to ____?
A. Backpressure or backsiphonage
B. Backsiphonage only
C. Periodic inspection
D. Sustained pressure
E. Toxic materials -CORRECTANSWER Backpressure or backsiphonage

A pipe restriction's flow velocity increase may allow ____?
A. Aspiration
B. Backpressure
C. Low turbulence
D. Pressure head
E. Pressure surges -CORRECTANSWER Aspiration

Water supply contamination from backflow may result in ____?
A. A bad taste
B. Coloration
C. Death
D. Odor or smell
E. Pipe wall mineral deposit flaking -CORRECTANSWER Death

To prevent backflow, an atmospheric vacuum breaker is primarily designed to ____?
A. Allow air into the outlet piping system
B. Create an elevation loop above ground
C. Introduce head loss
D. Prevent backpressure
E. Restrict velocity -CORRECTANSWER Allow air into the outlet piping system

, Atmospheric vacuum breakers will typically be located on ____?
A. Commercial irrigation systems
B. Fire-suppression systems
C. Plumbing fixtures or appliances
D. Utility storage tanks
E. Water service connections -CORRECTANSWER Plumbing fixtures or appliances

The mechanical component of an atmospheric vacuum breaker serves as an air-inlet
valve and a ____?
A. Check valve
B. Regulating valve
C. Relief valve
D. Shut-off valve
E. Test port -CORRECTANSWER Check valve

A deck-mounted atmospheric vacuum breaker's critical installation level is above the
outlet usage by ___?
A. 1 in. (2.5 cm)
B. 3 in. (7.6 cm)
C. 6 in. (15 cm)
D. 12 in. (30 cm)
E. 18 in. (46 cm) -CORRECTANSWER 1 in. (2.5 cm)

A hose-bibb connection is required to have a permanently installed ____?
A. Atmospheric vacuum breaker
B. Backflow preventer
C. Pressure vacuum breaker
D. Shut-off valve
E. Spill-resistant vacuum breaker -CORRECTANSWER Atmospheric vacuum breaker

Atmospheric vacuum breakers must not be subject to continuous water pressure for
more than ___ hr.
A. 3
B. 6
C. 12
D. 18
E. 24 -CORRECTANSWER 12

A submerged atmospheric vacuum breaker may be considered a(n) _____?
A. Backflow preventer
B. Cross-connection
C. Expensive elbow
D. Typical installation
E. Useful training photo -CORRECTANSWER . Cross-connection

Flow from the outlet of an atmospheric vacuum breaker must not reach a _____?

Document information

Uploaded on
June 1, 2026
Number of pages
17
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$17.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
13
Followers
1
Items
819
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions