Type ____ is multiconductor cable identified for use as underground service entrance cable.
✔Correct Answer-Type USE cable

Knife switch rated for more than 1200 Amps at 250Volts or less ✔Correct Answer-Can be used
only as isolating switch, shall not be opened under load

Track lighting with outlets in a bathroom is not allowed because ? ✔Correct Answer-Track
lighting has receptacle

Where internal combustion engines are used as the prime motor, an on site fuel supply shall be
provided with an on premise fuel supply sufficient for not less than ____ hours full demand
operation of the system ✔Correct Answer-6 hours

Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____
amperes shall be permitted to be supplied through a suitable attachment plug cap and hard
service cable cord. ✔Correct Answer-30 Amps

Where skin effect exist the ferromagnetic envelope shall be bonded at ____. ✔Correct
Answer-Both ends

GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the
____type. ✔Correct Answer-Locking

The maximum voltage drop from service point to the last over-current device in a dwelling unit?
✔Correct Answer-4%

Which of the following statements best describe the grounding requirement for central vacuum
outlet ✔Correct Answer-Accessible non current carrying metal parts are required to be
connected to an equipment grounding conductor.

In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by
at least two branch circuits, which ____permitted to originate from two separate transfer
switches on the emergency system ✔Correct Answer-Are permitted

Patient care areas of healthcare facilities ____ areas such as business offices, corridors,
lounges ,day rooms, or similar areas ✔Correct Answer-Do not include

,The patient care area is any portion of the healthcare facility where patients are intended to be
____or ____. ✔Correct Answer-Examined or treated

Each general care area patient bed location in a healthcare facility must be provided with four
____ or ____ duplex receptacles ✔Correct Answer-Single or two

A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical,
care on a 24 hour basis of ____ or more patients ✔Correct Answer-Four

Where installed to reduce electrical noise for electronic equipment, electrical continuity of the
metal raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic
fitting or spacer on electronic equipment ✔Correct Answer-Listed fitting

Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation
temperature rating not lower than 90°C (194°F) unless supplying a luminaiere marked as
suitable for a different insulation temperature ✔Correct Answer-3 inches

Manufactured wiring systems constructed with type MC cable shall be supported and secured
at intervals not exceeding ____ ft. ✔Correct Answer-6 ft

Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be
identified with a ____ that shall be visible with the screw installed ✔Correct Answer-Green
finish

Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the
window, cap, or other prominent part to distinguish them from fuses of higher ampere rating
✔Correct Answer-Hexagon

The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts
(volt-amperes) or the nameplate rating, which ever is larger, for each dryer served ? ✔Correct
Answer-5000 watts

Service conductors installed as unjacketed multiconductor cable shall have a minimum
clearance of ____ windows that are designed to be opened, doors, porches, stairs fire escape or
similar locations. ✔Correct Answer-3 ft (36 inches)

—— Cartridge fuses of the renewable type shall be permitted to be used only for replacement
in existing installation is where there is no evidence of over-fusing or tampering. ✔Correct
Answer-Class H

Branch circuit conductors within ____inches of the ballast shall have an insulation temperature
rating not lower it 90°C 194°F ✔Correct Answer-3" inches

The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. ✔Correct Answer-8

, In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground
plug ? ✔Correct Answer-Combination range hood/microwave oven

Type 3 Surge Protective devices can be installed on the load side of a branch circuit overcurrent
device up to the equipment served.if ____ the type 3 SPD connection must be a minimum 30'ft
of conductor a distance from the service or separately derived system disconnect ✔Correct
Answer-Included in the manufactures instructions

Which flexible cable is Allowed to be used for electric vehicle charging station 300 Volts ?
✔Correct Answer-EVJ

Type ____ fuse adapters shall be designed so that once inserted in a fuse holder that cannot be
removed ✔Correct Answer-Type S fuse

Service drops Installed over roof shall have a vertical clearance of ____ above the roof surface,
and unless a lesser distance is permitted by and exceptions ✔Correct Answer-8'ft

Class 2 and Class 3 circuits shall not be placed in any enclosure, raceway, cable, or similar fittings
with conductors of Class 1 or electric light or power conductors, unless ____. ✔Correct
Answer-Separated by barrier

In the critical care areas of health care centers, each patient bed shall be provided with a
minimum of ____ duplex receptacles ✔Correct Answer-3 duplex (6 single)

The equipment system shall supply major electric ____ necessary for patient care and basic
hospital operation ✔Correct Answer-Equipment

The essential electrical system in a healthcare facility shall be compromised of the ✔Correct
Answer-emergency system and the: equipment system

Locations were flammable anesthetics are employed are class I,Division I locations that shall
extend ✔Correct Answer-upwards to a level 5'ft above the floor

In a healthcare facility receptacles and attachment plugs in a hazardous (classified) location with
an anesthizing area shall be listed for use in class I group ____ locations ✔Correct Answer-
Group C

In anesthetic,areas health care equipment frequently in contact with bodies of persons shall not
exceed ____ volts. ✔Correct Answer-10 Volts

In anesthetic areas, low-voltage equipment that is frequently in contact with the bodies of
persons or has exposed current-carrying elements shall ✔Correct Answer-operate on an

Document information

Uploaded on
May 31, 2026
Number of pages
19
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$20.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Studyclub
3.6
(14)
Sold
70
Followers
1
Items
13412
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions