Type ____ is multiconductor cable identified for use as underground service entrance cable. - Answer Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less - Answer Can be used only as isolating switch, shall not be opened under load Track lighting with outlets in a bathroom is not allowed because? - Answer Track lighting has receptacle Where internal combustion engines are used as the prime motor, an on-site fuel supply shall be provided with an on-premise fuel supply sufficient for not less than ____ hours full demand operation of the system - Answer 6 hours Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. - Answer 30 Amps

Content preview

NYC Master Electrician Exam Practice Questions
with Expert Solutions

Type ____ is multiconductor cable identified for use as underground service entrance cable. - Answer
Type USE cable



Knife switch rated for more than 1200 Amps at 250Volts or less - Answer Can be used only as isolating
switch, shall not be opened under load



Track lighting with outlets in a bathroom is not allowed because? - Answer Track lighting has receptacle



Where internal combustion engines are used as the prime motor, an on-site fuel supply shall be
provided with an on-premise fuel supply sufficient for not less than ____ hours full demand operation of
the system - Answer 6 hours



Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes
shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. -
Answer 30 Amps



Where skin effect exist the ferromagnetic envelope shall be bonded at ____. - Answer Both ends



GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type.
- Answer Locking



The maximum voltage drop from service point to the last over-current device in a dwelling unit? -
Answer 4%



Which of the following statements best describe the grounding requirement for central vacuum outlet -
Answer Accessible non current carrying metal parts are required to be connected to an equipment
grounding conductor.

,In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least
two branch circuits, which ____permitted to originate from two separate transfer switches on the
emergency system - Answer Are permitted



Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day
rooms, or similar areas - Answer Do not include



The patient care area is any portion of the healthcare facility where patients are intended to be ____or
____. - Answer Examined or treated



Each general care area patient bed location in a healthcare facility must be provided with four ____ or
____ duplex receptacles - Answer Single or two



A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a
24 hour basis of ____ or more patients - Answer Four



Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal
raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or
spacer on electronic equipment - Answer Listed fitting



Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation
temperature rating not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a
different insulation temperature - Answer 3 inches



Manufactured wiring systems constructed with type MC cable shall be supported and secured at
intervals not exceeding ____ ft. - Answer 6 ft



Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be identified
with a ____ that shall be visible with the screw installed - Answer Green finish



Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the window, cap,
or other prominent part to distinguish them from fuses of higher ampere rating - Answer Hexagon

, The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts (volt-
amperes) or the nameplate rating, which ever is larger, for each dryer served ? - Answer 5000 watts



Service conductors installed as unjacketed multiconductor cable shall have a minimum clearance of
____ windows that are designed to be opened, doors, porches, stairs fire escape or similar locations. -
Answer 3 ft (36 inches)



—— Cartridge fuses of the renewable type shall be permitted to be used only for replacement in existing
installation is where there is no evidence of over-fusing or tampering. - Answer Class H



Branch circuit conductors within ____inches of the ballast shall have an insulation temperature rating
not lower it 90°C 194°F - Answer 3" inches



The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. - Answer 8



In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground plug ? -
Answer Combination range hood/microwave oven



Type 3 Surge Protective devices can be installed on the load side of a branch circuit overcurrent device
up to the equipment served.if ____ the type 3 SPD connection must be a minimum 30'ft of conductor a
distance from the service or separately derived system disconnect - Answer Included in the
manufactures instructions



Which flexible cable is Allowed to be used for electric vehicle charging station 300 Volts ? - Answer EVJ



Type ____ fuse adapters shall be designed so that once inserted in a fuse holder that cannot be removed
- Answer Type S fuse



Service drops Installed over roof shall have a vertical clearance of ____ above the roof surface, and
unless a lesser distance is permitted by and exceptions - Answer 8'ft



Class 2 and Class 3 circuits shall not be placed in any enclosure, raceway, cable, or similar fittings with
conductors of Class 1 or electric light or power conductors, unless ____. - Answer Separated by barrier

Document information

Uploaded on
May 29, 2026
Number of pages
23
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Topscore101
5.0
(1)
Sold
5
Followers
0
Items
1880
Last sold
4 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions