____ ______ climate necessitates slightly lower airflow 325-350 cfms per ton of cooling correct answer High humidity climates A _____ refrigerant blend is a mixture of two or more refrigerant that can separate or fractionate into its original components correct answer Zeotropic a globally recognized, independent safety certification organization. Approves additional refrigeration system components. correct answer Underwriters laboratories UL A proper ______/_____ procedure should be used when the equipment is de-energized correct answer Lockout/tagout A refrigerant ODP measures what? correct answer ozone depletion potential, It's ability to destroy ozone in the stratosphere A term used to describe the range of boiling or condensing temperatures at a given pressure correct answer Temperature glide After installation, the refrigerant piping for an A2 L system must be correct answer Pressurized with dry nitrogen to perform a leak test After reaching the required recovery level on a system that is charged with a 2L refrigerant a _____ sweep must be done to remove any residual refrigerant vapor correct answer Nitrogen

Content preview

A2L STUDY GUIDE QUESTIONS WITH ACCURATE
ANSWERS
____ ______ climate necessitates slightly lower airflow 325-350 cfms per ton of
cooling correct answer High humidity climates


A _____ refrigerant blend is a mixture of two or more refrigerant that can
separate or fractionate into its original components correct answer Zeotropic


a globally recognized, independent safety certification organization. Approves
additional refrigeration system components. correct answer Underwriters
laboratories UL


A proper ______/_____ procedure should be used when the equipment is de-
energized correct answer Lockout/tagout


A refrigerant ODP measures what? correct answer ozone depletion potential, It's
ability to destroy ozone in the stratosphere


A term used to describe the range of boiling or condensing temperatures at a
given pressure correct answer Temperature glide


After installation, the refrigerant piping for an A2 L system must be correct
answer Pressurized with dry nitrogen to perform a leak test


After reaching the required recovery level on a system that is charged with a 2L
refrigerant a _____ sweep must be done to remove any residual refrigerant vapor
correct answer Nitrogen

, All additional system components such as filter line dryers, receivers, and
accumulators must be designed, tested, and __ ____ in order to be installed on a
system that is charged with A2L refrigerant correct answer UL listed


An ______ refrigerant blend behaves like a simple compound refrigerant. It
follows a single pressure/temperature chart and does not separate into its
component parts. correct answer Azeotropic


An industry accepted mitigation strategy used when installing equipment charged
with a two hour refrigerant is correct answer Permanent space ventilation


An upper case letter designation is used when refrigerant blends are correct
answer Composed of the same refrigerant, but with different percentages of each


ASHRAE correct answer American Society of Heating, Refrigerating and Air-
Conditioning Engineers


ASHRAE Standard 15 correct answer a safety standard for refrigeration systems
that outlines safe practices for design, construction, installation, and operation


ASHRAE Standard 34 correct answer An ASHRAE standard that names refrigerants
and assigns safety classifications according to their flammability and toxicity.


Ashray standard 15 Requires that some systems that are charged with a _____
_____ require an indoor fan to be energized by an active refrigerant sensor as a
mitigation step to keep the flammable refrigerant levels below it's _____ ____
______ correct answer Flammable refrigerant, lower flammability level LFL

Document information

Uploaded on
May 28, 2026
Number of pages
11
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
starwid
3.4
(5)
Sold
20
Followers
1
Items
11388
Last sold
2 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions