D025 FINAL PAPER SOLVED QUESTIONS
WITH FULL PRACTICE SOLUTION
●● Under the dash
Answer: Where is connector C250 located?
●● Shown in their normal position
Answer: All switches illustrated in schematics are...........................
●● 86 and 85
Answer: When testing a relay using an ohmmeter, which two terminals
should be touched to measure the coil resistance?
●● Technician A only
Technician B only
Both technician A and B
Answer: Technician A says that a good relay should measure between 60
and 100 ohms across the coil terminals. Technician B says that OL
should be displayed on an ohmmeter when touching terminals 30 and
87. Which technician is correct?
●● 87a
Answer: Which relay terminal is the normally closed (NC) terminal?
, ●● Technician A only
Technician B only
Both technician A and B
Answer: Technician A says that there is often more than one circuit
being protected by each fuse. Technician B says that more than one
circuit often shares a single ground connector. Which technician is
correct?
●● Technician A only
Technician B only
Neither technician A and B
Answer: Two technician are discussing finding a short to ground using a
test light. Technician A says that the test light, connected in place of the
fuse, will light when the circuit that has the short is disconnected.
Technician B says that the test light should be connected to the
positive(+) and negative(-) terminals of a battery during this test. Which
technician is correct?
●● Tone generator
Test light
Gauss gauge
All of the above
Answer: A short circuit can be located using a................
WITH FULL PRACTICE SOLUTION
●● Under the dash
Answer: Where is connector C250 located?
●● Shown in their normal position
Answer: All switches illustrated in schematics are...........................
●● 86 and 85
Answer: When testing a relay using an ohmmeter, which two terminals
should be touched to measure the coil resistance?
●● Technician A only
Technician B only
Both technician A and B
Answer: Technician A says that a good relay should measure between 60
and 100 ohms across the coil terminals. Technician B says that OL
should be displayed on an ohmmeter when touching terminals 30 and
87. Which technician is correct?
●● 87a
Answer: Which relay terminal is the normally closed (NC) terminal?
, ●● Technician A only
Technician B only
Both technician A and B
Answer: Technician A says that there is often more than one circuit
being protected by each fuse. Technician B says that more than one
circuit often shares a single ground connector. Which technician is
correct?
●● Technician A only
Technician B only
Neither technician A and B
Answer: Two technician are discussing finding a short to ground using a
test light. Technician A says that the test light, connected in place of the
fuse, will light when the circuit that has the short is disconnected.
Technician B says that the test light should be connected to the
positive(+) and negative(-) terminals of a battery during this test. Which
technician is correct?
●● Tone generator
Test light
Gauss gauge
All of the above
Answer: A short circuit can be located using a................