Diesel Tech
Systems
ASE Practice
Quiz _ Exam
Test_Preparation
Electrical
Diesel Tech
Systems
Guide.pdf
ASE Practice
Quiz _ Exam
Test_Preparation
Electrical Systems
Guide.pdf
Quiz _ Exam Preparation Guide.pdf
Diesel Tech ASE
Practice Test:
Electrical Systems
Quiz | Exam
Preparation Guide
Diesel Tech ASE Practice Test_ Electrical
Diesel Tech
Systems
ASE Practice
Quiz _ Exam
Test_Preparation
Electrical
Diesel Tech
Systems
Guide.pdf
ASE Practice
Quiz _ Exam
Test_Preparation
Electrical Systems
Guide.pdf
Quiz _ Exam Preparation Guide.pdf
,Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf
Terms in this set (44)
A resistance test was performed on an open toggle B. B only
switch and the result is 5.857 megohms. Technician A says
that the switch is faulty because the reading is beyond
the specifications. Technician B says that the switch has
over 5 million ohms of resistance. Who is correct?
A. A only
B. B only
C. Both A and B
D. Neither A nor B
Which of the following conditions could cause the power A. Broken connector at the power lock switch
locks to fail to operate?
A. Broken connector at the power lock switch
B. Closed power lock circuit breaker
C. An oversized fuse
D. An oversized wire repair in the power lock circuit
Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf
, Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf
When using a 12 volt, unpowered test lamp to test for B. The battery should be disconnected
voltage, all of the following are true EXCEPT:
A. The test lamp may be connected to the battery
ground
B. The battery should first be disconnected
C. The test lamp may be connected to a chassis ground
D. The test lamp will not illuminate when probed into the
circuit at a point after the load
After removing a 30 amp circuit breaker from a fuse D. Neither A nor B
panel, a technician checks continuity across its terminals
with a digital multimeter (DMM). Technician A says that
the current from the ohmmeter will open the circuit
breaker. Technician B says the ohmmeter should read
infinity if the circuit breaker is good. Who is correct?
A. A only
B. B only
C. Both A and B
D. Neither A nor B
Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf Diesel Tech ASE Practice Test_ Electrical Systems Quiz.pdf