CLASS D WATER LICENSE TEXAS EXAM
2026 LATEST UPDATE QUESTIONS AND
CORRECT VERIFIED ANSWERS ALREADY
GRADED A+

_____ allows uniform pump rates, supplies water for firefighting, and
provides time for disinfection. - ANS-Storage



Ground storage at a surface water treatment plant is called a _____. -
ANS-clear well



The TCEQ requires storage tanks to have covered vents, an airtight cover,
overruns, and _____. - ANS-entry ports



If ground storage is the only storage, capacity must be _____ gallons per
connection. Otherwise, total storage capacity (elevated storage included)
must be _____ gallons per connection. - ANS-200 gallons per
connection

200 gallons per connection



If a 30-inch diameter access opening is not provided in a storage tank, the
primary roof access must not be less than _____ inches. - ANS-30 inches



Storage must be painted, disinfected, and maintained according to OSHA
standards. (true/false) - ANS-false (AWWA standards)



No paint, coating, or wax containing _____ is allowed in storage tanks. -
ANS-lead

,Storage tank coatings for contact with potable water must be approved by
EPA, the National Sanitation Foundation, or the Food and Drug
Administration. (true/false) - ANS-true



_____ is a tank, usually steel, supported aboveground on a tower. - ANS-
Elevated storage



Pressure from an elevated tank is maintained by the _____. - ANS-height
of the water column



In storage tanks, each foot of water column produces _____ psi. - ANS-
0.433 psi



Water stored at least _____ feet above the highest service connection
provides the state's minimum normal operating pressure of _____ psi. -
ANS-80.85 feet above the highest connection

35 psi



A _____ is a tank resting on the ground that is greater in height than
diameter. - ANS-standpipe



Pressure inside a _____ tank is provided by air mechanically compressed
against the water surface. - ANS-hydropneumatic tank



The exterior and interior of ground, elevated, standpipe, and pressure
tanks must be inspected _____. - ANS-yearly



Storage tank inspection results must be kept at least _____ years. - ANS-5
years



_____ is an electrochemical method of preventing corrosion of the interior
of metal tanks. - ANS-Cathodic protection

,Ownership signs must include the utility name and emergency phone
number at each production, treatment, or storage site. (true/false) - ANS-
true



Chain link fence material must leave a gap at the ground to trim grass.
(true/false) - ANS-false



The state requires stored water to have a disinfectant demand. (true/false)
- ANS-false (it requires a disinfectant residual)



After construction or maintenance of a storage tank, a _____ sample must
be taken after filling the tank. - ANS-bacteriological sample



If the bacteriological sample from a storage tank is negative, more
samples must be taken until two consecutive samples are positive.
(true/false) - ANS-false (if negative you're good to go)



Critical safeguards of a distribution system include a chlorine residual,
adequate pressure, bacteriological sampling, and _____ control. - ANS-
cross-connection control



The TCEQ requires that distribution pressure never fall below _____ psi,
even during emergencies, and normal distribution pressure must be at
least _____ psi. - ANS-never fall below 20 psi

35 psi (normal distribution)



Material used in water line construction must meet OSHA specifications
and should not affect the taste, odor, or quality of the water. (true/false) -
ANS-false (AWWA specifications)



Plastic pipe must be NSF approved and have an ASTM pressure rating of at
least _____ psi or a standard dimension ratio of _____. - ANS-150 psi

dimension ratio of 26

, Select pipe on the basis of strength, length carrying capacity, durability,
ease of installation, availability, soil conditions, and cost. (true/false) -
ANS-false (length shouldn't be a consideration)



Prior to January 1, 2014, pipe and fittings containing more than 8.0% lead,
or solders and flux containing more than 0.2% lead, are prohibited in a
public water supply. (true/false) - ANS-true



_____ valves cut off sections of a system. - ANS-Isolating valves



_____ solves problems of taste, odor, red water, or bad samples. - ANS-
Flushing



The _____ meter is the most common design for residential use. - ANS-
positive displacement meter



Mains must be no closer than _____ feet, in all directions, from sewers or
manholes. - ANS-9 feet



Trenches for laying six-inch and larger pipe must be at least _____ inches
wide and ________ inches wider than the pipe diameter. - ANS-18 inches
wide

12 inches wider



The top of a pipe in a trench must have at least ________ inches of cover. -
ANS-24 inches



Do not work in a trench ________ feet or deeper unless it is protected from
cave-in. - ANS-5 feet



Using timber, plywood, or commercial devices to support an excavation is
known as ________. - ANS-shoring

Document information

Uploaded on
May 17, 2026
Number of pages
33
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$24.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
1
Followers
0
Items
255
Last sold
11 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions