Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 8 pages
Exam (elaborations)

A+ Advanced Aboveground Storage Tank Engineering & Integrity Assessment Exam Covering API 653 Inspection Requirements, API 650 Construction Standards, API 579 Fitness-for-Service Analysis, API 580 Risk Based Inspection (RBI), API 652 Tank Bottom Linings,

Document preview thumbnail
Preview 2 out of 8 pages

A+ Advanced Aboveground Storage Tank Engineering & Integrity Assessment Exam Covering API 653 Inspection Requirements, API 650 Construction Standards, API 579 Fitness-for-Service Analysis, API 580 Risk Based Inspection (RBI), API 652 Tank Bottom Linings, API 651 Cathodic Protection Systems, API 2201 Hot Tapping Procedures, ASME Section V NDE Requirements, ASME Section IX Welding Procedure Qualification, AWS D1.1 Structural Welding Standards, ASTM Material Testing and Impact Requirements, API 620 Low Pressure Storage Tank Design, Shell and Bottom Plate Corrosion Evaluation, Tank Settlement Analysis, Weld Defect Acceptance Criteria, Fitness-for-Service Stress Assessment, Fatigue and Brittle Fracture Evaluation, Cathodic Protection Design, Internal Lining Performance, Hot Work Safety Practices, Nozzle Installation and Reinforcement Design, Lap Patch Repair Engineering, Frangible Roof Design, External Pressure and Vacuum Conditions Exam Questions Verified and Provided with Complete A+ Graded Answers Latest Updated 2026 Per API 653 , with of the following is required when converting an existing tank to operation at elevated temperatures when it was not originally designed and constructed to API 650, Appendix M? The Shell to bottom joint shall be evaluated for fatigue When removing an existing tank bottom, all arc-gouged areas of the tank shell-to-bottom shall be: examined using magnetic particle inspection, and defective areas repaired and re-examined. If RBI assessment has been conducted and the tank has cathodic protection plus a thin-film lining, the maximum inspection interval is: 14 years When installing a new nozzle in a tank of unknow material, what stress value should be used to calculate the required shell thickness and reinforcement? 20,000 lbf/in2 In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a wet environment. may double with every 18 °F increase in temperature above 77 °F. Grade 350W/50W is acceptable for tank plate to a maximum thickness of: 45mm (1.75in) if fully killed and made to a fine grain practice. If an RBI assessment has been conducted and the tank has a release prevention barrier, the maximum initial inspection interval is: 25 years As an alternative to the procedures in API 653 for the evaluation of any thinning of the tank shell below minimum required wall thickness may be evaluated for continued service using which code?

Content preview

A+ Advanced Aboveground Storage Tank Engineering & Integrity
Assessment Exam Covering API 653 Inspection Requirements, API
650 Construction Standards, API 579 Fitness-for-Service Analysis,
API 580 Risk Based Inspection (RBI), API 652 Tank Bottom Linings,
API 651 Cathodic Protection Systems, API 2201 Hot Tapping
Procedures, ASME Section V NDE Requirements, ASME Section IX
Welding Procedure Qualification, AWS D1.1 Structural Welding
Standards, ASTM Material Testing and Impact Requirements, API
620 Low Pressure Storage Tank Design, Shell and Bottom Plate
Corrosion Evaluation, Tank Settlement Analysis, Weld Defect
Acceptance Criteria, Fitness-for-Service Stress Assessment, Fatigue
and Brittle Fracture Evaluation, Cathodic Protection Design, Internal
Lining Performance, Hot Work Safety Practices, Nozzle Installation
and Reinforcement Design, Lap Patch Repair Engineering, Frangible
Roof Design, External Pressure and Vacuum Conditions Exam
Questions Verified and Provided with Complete A+ Graded Answers
Latest Updated 2026




Per API 653 , with of the following is required when converting an existing tank to operation at
elevated temperatures when it was not originally designed and constructed to API 650,
Appendix M?

The Shell to bottom joint shall be evaluated for fatigue




When removing an existing tank bottom, all arc-gouged areas of the tank shell-to-bottom shall
be:

examined using magnetic particle inspection, and defective areas repaired and re-examined.

, If RBI assessment has been conducted and the tank has cathodic protection plus a thin-film
lining, the maximum inspection interval is:

14 years




When installing a new nozzle in a tank of unknow material, what stress value should be used to
calculate the required shell thickness and reinforcement?

20,000 lbf/in2




In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a wet
environment.

may double with every 18 °F increase in temperature above 77 °F.




Grade 350W/50W is acceptable for tank plate to a maximum thickness of:

45mm (1.75in) if fully killed and made to a fine grain practice.




If an RBI assessment has been conducted and the tank has a release prevention barrier, the
maximum initial inspection interval is:

25 years




As an alternative to the procedures in API 653 for the evaluation of any thinning of the tank
shell below minimum required wall thickness may be evaluated for continued service using
which code?

API RP 579, section 4, 5 or 6.

Document information

Uploaded on
May 13, 2026
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.98

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
LectDeniz
5.0
(1)
Sold
21
Followers
16
Items
5281
Last sold
10 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions