Fire Safety Director / Fire Life Safety Director On-Site
Prep Exam||Verified Exam!!!||, NYC Fire Code & NFPA
Standards, 2026/2027-Question Practice
Examination||Newest Exam!!!


The water valve that controls water flow in a sprinkler
system has a wheel and an exposed stem (if in the open
position). This valve is called: - Answer-The OS & Y valve


A Fire Department Connection (FDC) that supplies water
to standpipe system only would be colored: - Answer-Red


Standpipe systems are generally required in buildings
which are more than __________ feet height - Answer-75


In a fully sprinklered building, the number of extra sprinkler
heads required to be kept at the main water control valve
is: - Answer-At least 6


It is an effective means of suppressing fire, and at the
same time transmits an alarm to the Fire Department. This
statement describes: - Answer-An automatic sprinkler
system

,2|Page




With regard to the height of stock in a sprinklered
storeroom, it is most correct to state that the stock must be
placed: - Answer-NOT closer than 18" to the sprinkler
piping


Who is required to designate a impairment coordinator to
be responsible for complying with the Out-of-service
sprinkler system requirements of the Fire Code? - Answer-
The Building Owner


The Fire Brigade duties include: - Answer-. Contact FSD
for the fire details darning evacuation
. Initially report to floor below the fire, and assist in
evacuation
. Investigate the cause for the alarm and attempting to
control spread fire


A CoF is required for a FSD for a building classified in the
Building Code as occupancy group B, occupied by: -
Answer-- More than 100 persons above the street level
- More than 100 persons below the street level

,3|Page


- More than a total of 500 persons in the entire building


The FSD must make sure that the hallways and stairways
are: - Answer-- Properly Illuminated
- Free from garbage accumulation
- Free from obstruction


As a general rule, during a fire, most hazardous locations
in a high-rise building would be: - Answer-The fire floor
and the floor above the alarm
Which is NOT a part of the monthly visual inspection of the
standpipe? - Answer-Conduct a hydrostatic test of the
standpipe system


What is the main purpose of the roof manifold? - Answer-
Firefighting and testing of the standpipe system


Which best describes the primary purpose of the upper
check valve located under a roof water storage tank? -
Answer-To stop water from going into the tank

, 4|Page


If water is flowing from a ball drip connection, it might
mean? - Answer-The lower check valve may be defective


What is the purpose of the OS&Y valve? - Answer-To stop
or regulate the flow of water through the system


"Automatic dry" sprinkler systems are filled with? - Answer-
Air under pressure


Standpipe system supply valves under normal conditions
are kept? - Answer-Opened and chained


The color of the FDC caps for a non-automatic system
are? - Answer-Aluminum


How often will a standpipe system (office building) be
required to perform a hydrostatic test to demonstrate its
suitability for fire department use? (minimum) - Answer-
Five years


Sprinkler heads that get paint on them - Answer-Must be
replaced with a new head

Document information

Uploaded on
April 22, 2026
Number of pages
41
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$25.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Sold
80
Followers
6
Items
6052
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions