This document covers Master Electrician Exam Review material, focusing on advanced electrical trade concepts such as complex circuit analysis, electrical codes and standards, system design, load calculations, troubleshooting, grounding and bonding, and safety compliance. It includes structured review notes and exam-focused content designed to support comprehensive certification preparation. The material is intended to help candidates consolidate advanced electrical knowledge and prepare effectively for master electrician licensing exams.

Content preview

Master Electrician Exam Review – Electrical Trade
Certification – study material

branch circuit - correct answer ✔✔That portion of a wiring system extending beyond the final
overcurrent device is called the:



Calculated load - correct answer ✔✔The final sum of the computed loads, based on the
minimum code requirements, is the



Resistance - correct answer ✔✔As compared to #10, a #8 wire of the same Iength has less:



0.001 inch - correct answer ✔✔One circular mil is the area of a circle whose diameter is:



1,000,000 cm - correct answer ✔✔A round bus-bar one inch in diameter, has a circular mil area
of:



four times as great - correct answer ✔✔A copper wire with twice the diameter of another wire
has a current carrying capacity:



10.4 - correct answer ✔✔The specific resistance of copper wire @ 20° C in ohms per circular mil
ft. is



permit current to flow - correct answer ✔✔Conductance of an electric circuit is that property
that will:



1O ohms - correct answer ✔✔The equivalent value of 0.1 mho is

,directly proportional to its length - correct answer ✔✔The resistance of copper wire is:



Feeder - correct answer ✔✔The portion of a wiring system between a point of distribution and
the branch circuit overcurrent device is



locking - correct answer ✔✔GFCI protection at a carnival is not required for equipment at circuit
if the receptacle is of the ____________type



not less than 1 1/4 in. from - correct answer ✔✔Where cables or nonmetallic raceways are
installed through bored.holes in joists, rafters, or wood members;holes shall be bored so that
the edge of the hole is the nearest edge -of the wood member.



located on a balcony accessible only to qualified persons

located in a room only accessible to

qualified persons

elevated 8 ft or more above floor or other working surface - correct answer ✔✔To guard live
parts over 50V but less than 600V, equipment is permitted to be



12Ft - correct answer ✔✔Overhead feeder conductors shall have a minimum __________
vertical clearance over residential property and driveways, as well as those commercial areas
not subject to truck traffic, where the voltage is limited to 300 volts-to-ground.



36 inches - correct answer ✔✔Where rear access is required to work on de-energized parts on
the back of enclosed equipment, a minimum working space of horizontally shall be provided.



50' - correct answer ✔✔What is the maximum run length of a 18AWG fixture wire that is
tapped on to a 20 amp branch circuit?

, power supply failure - correct answer ✔✔When the service disconnecting means is a power-
operated switch or circuit breaker, it shall be able to be opened by hand in the event of a



2 in of concrete - correct answer ✔✔Conductors are considered outside a buildings when they
are buried under not less than



8 - correct answer ✔✔In straight pull, the length of the box shall not be less than. ____times
the trade size of the largest raceway.



18" - correct answer ✔✔At least one receptacle outlet shall be installed within of the top of a
show window for each 12 linear feet measured horizontally across its length



1000A - correct answer ✔✔Ground-fault protection of equipment shall be provided fro solidly
grounded wye electrical services of more than 150 volts-to-ground, but not exceeding 600V
phase-to..phase for each service disconnecting means rated



18" - correct answer ✔✔Receptacle outlets in floors shall not be counted as part of the required

number of receptacle outlets unless located within ______ of the wall



50V - correct answer ✔✔Exposed live parts of motors and controllers operating at or more
between terminals shall be guarded against accidental contact by enclosure or by location



5' - correct answer ✔✔Lighting track shall not be installed less than______ above the finished
floor except' where protected from physical damage or where the track operates at less than 30
V rms, open-circuit voltage



4 - correct answer ✔✔Each general care area patient bed location shall be provided with a
minimum of_______receptacles, which can be single, duplex, or a combination with each
duplex counting as two receptacles

Document information

Uploaded on
April 16, 2026
Number of pages
18
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$22.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BravelRadon
3.5
(166)
Sold
972
Followers
542
Items
54164
Last sold
15 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions