• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 164 pages
Exam (elaborations)

NYC MASTER ELECTRICIAN EXAM Newest Exam Preparation Newest With Complete Questions And Correct Detailed Answers| Brand New Version

Document preview thumbnail
Preview 4 out of 164 pages

NYC MASTER ELECTRICIAN EXAM Newest Exam Preparation Newest With Complete Questions And Correct Detailed Answers| Brand New Version Type ____ is multiconductor cable identified for use as underground service entrance cable. - answer_Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less - answer_Can be used only as isolating switch, shall not be opened under load Track lighting with outlets in a bathroom is not allowed because ? - answer_Track lighting has receptacle Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided with an on premise fuel supply sufficient for not less than ____ hours full demand operation of the system - answer_6 hours Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. - answer_30 Amps 1 | P a g e Where skin effect exist the ferromagnetic envelope shall be bonded at ____. - answer_Both ends GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. - answer_Locking The maximum voltage drop from service point to the last over current device in a dwelling unit? - answer_4% Which of the following statements best describe the grounding requirement for central vacuum outlet - answer_Accessible non current carrying metal parts are required to be connected to an equipment grounding conductor. In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system - answer_Are permitted Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or similar areas - answer_Do not include 2 | P a g e The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. - answer_Examined or treated Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____ duplex receptacles - answer_Single or two A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more patients - answer_Four Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment - answer_Listed fitting Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a different insulation temperature - answer_3 inches

Content preview

NYC MASTER ELECTRICIAN EXAM Newest Exam
Preparation Newest With Complete Questions
And Correct Detailed Answers| Brand New Version
Type ____ is multiconductor cable identified for use as
underground service entrance cable. - answer_Type USE cable


Knife switch rated for more than 1200 Amps at 250Volts or less
- answer_Can be used only as isolating switch, shall not be
opened under load


Track lighting with outlets in a bathroom is not allowed because
? - answer_Track lighting has receptacle


Where internal combustion engines are used as the prime
motor, an on site fuel supply shall be provided with an on
premise fuel supply sufficient for not less than ____ hours full
demand operation of the system - answer_6 hours


Fixed in place X-ray equipment properly supplied by a branch
circuit rated at not over ____ amperes shall be permitted to be
supplied through a suitable attachment plug cap and hard
service cable cord. - answer_30 Amps


1|Page

,Where skin effect exist the ferromagnetic envelope shall be
bonded at ____. - answer_Both ends


GFCI protection at a carnival is not required for equipment at
circuit if the receptacle is of the ____type. - answer_Locking


The maximum voltage drop from service point to the last over-
current device in a dwelling unit? - answer_4%


Which of the following statements best describe the grounding
requirement for central vacuum outlet - answer_Accessible non
current carrying metal parts are required to be connected to an
equipment grounding conductor.


In healthcare facilities, patient bed receptacles located in
general care areas shall be supplied by at least two branch
circuits, which ____permitted to originate from two separate
transfer switches on the emergency system - answer_Are
permitted


Patient care areas of healthcare facilities ____ areas such as
business offices, corridors, lounges ,day rooms, or similar areas
- answer_Do not include

2|Page

,The patient care area is any portion of the healthcare facility
where patients are intended to be ____or ____. -
answer_Examined or treated


Each general care area patient bed location in a healthcare
facility must be provided with four ____ or ____ duplex
receptacles - answer_Single or two


A hospital is a building or portion thereof used for medical,
psychiatric,obstetrical , or surgical, care on a 24 hour basis of
____ or more patients - answer_Four


Where installed to reduce electrical noise for electronic
equipment, electrical continuity of the metal raceways shall not
be required and metal raceway can terminate a (an) ____
nonmetallic fitting or spacer on electronic equipment -
answer_Listed fitting


Feeder and branch circuit conductors within ____ inches of a
Ballast shall have an insulation temperature rating not lower
than 90°C (194°F) unless supplying a luminaiere marked as
suitable for a different insulation temperature - answer_3
inches
3|Page

, Manufactured wiring systems constructed with type MC cable
shall be supported and secured at intervals not exceeding ____
ft. - answer_6 ft


Where a main bonding jumper or a system bonding jumper is a
screw only the screw shall be identified with a ____ that shall
be visible with the screw installed - answer_Green finish


Plug fuses a 15 amperes and lower rating shall be identified by
a ____ configuration of the window, cap, or other prominent
part to distinguish them from fuses of higher ampere rating -
answer_Hexagon


The load for household electric clothes dryer's in a dwelling
unit(s) shall be either ____ watts (volt-amperes) or the
nameplate rating, which ever is larger, for each dryer served ? -
answer_5000 watts


Service conductors installed as unjacketed multiconductor
cable shall have a minimum clearance of ____ windows that are
designed to be opened, doors, porches, stairs fire escape or
similar locations. - answer_3 ft (36 inches)


4|Page

Document information

Uploaded on
April 3, 2026
Number of pages
164
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$22.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
49
Followers
3
Items
567
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions