Med Gas Study Guide Questions And Answers Updated 2027 oxygen cylinders in use and in storage shall be prevented from reaching temperatures in excess of how many degrees Fahrenheit? - ANSWER -125^o degrees non-mandated fundamentals and recommended guidelines for medical gas and vacuum systems shall be located in the ________________ of the NFPA 99 code of ASSE 6000 standards. - ANSWER -annexes or appendices the level of sedation allowed for use in a category 2 dental health facility is limited to which of the following? - ANSWER -moderate and minimal sedation what is the standard gauge pressure (psi) for nitrogen gas service? - ANSWER 55-185 in a category 1 health care facility, what is the maximum length (feet) allowed for a nonmetalic flexible connector to connect to the manifold in a medical gas piping system? - ANSWER -they shall be no longer than necessary in compliance with NFPA 70, new wiring is installed underground form (from?) the source to the junction box entering the building. what is the minimum number of sets of wires to connect the initiating device with the junction box? - ANSWER -1 which of the following fittings is NOT permitted for joining vacuum distribution pipeline systems? - ANSWER -non-removable push-fit medical air sources shall be sued (used ?) only for ________ and human respiration - ANSWER -calibration of medical respiratory devices in central supply systems using gas cylinders, each header shall have a __________ valve to prevent backflow and to permit service to the header. - ANSWER -check WAGD networks shall provide a WAGD inlet in all locations where __________ is intended to be administered. - ANSWER -nitrous oxide which is a permitted use of the medical-surgical vacuum system? - ANSWER waste anesthetic gas disposal which of the following is an instrument air quality requirement? - ANSWER -it shall be compliant with Instrument Air section ANSI/ISA S-7 0.01 Riser valves are those valves located where? - ANSWER -in the riser adjacent to the main line all positive-pressure supply systems shall be provided with means to control the final line pressure at the source and include _________. - ANSWER -all of the above: controls that are able to provide 100 percent capacity & protection against overpressure & the ability to service or replace components while maintaining normal operation during a patient emergency, when NFPA 99 code may be superseded by __________ actions shall be reviewed and documented for future events. - ANSWER -a medical professional when an installer installs products or devices not designated by code, items shall have supporting technical documentation approved by which of the following? - ANSWER -AHJ Prior to the installation of a manufactured assembly, documentation shall be provided for all EXCEPT which of the following tests? - ANSWER -cross connection installers shall have documentation indicating which of the following piping materials have been certified for use in a medical gas distribution system? - ANSWER -ASTM B819 hard drawn copper tube maintenance of which of the following on site, supporting documentation is required of a medical gas installer? - ANSWER -brazing qualification and procedure a medical air portioning system shall have a minimum of how many recorders in order to record system performance and air quality for a period of no less than 24 hours? - ANSWER -1 a wireless communication device is employed in a medical gas or vacuum warning system. which type of supervision is required for this device? - ANSWER -the device will be supervised such that failure of communication shall initiate an alarm the removal of components with a source system for repair and re-installation or for replacement shall be treated as new work for the purposes of testing whenever such work involves which of the following? - ANSWER -cutting and/or brazing new piping category 2 Dental Gas and Vacuum Systems require documentation for the installation which of the following? - ANSWER -oxygen and nitrous oxide category 1 facility, which of the following item(s) is correct regarding the standing vacuum test for vacuum piping? - ANSWER -during the test the source of the test vacuum shall be disconnected from the piping system the final connection between new piping and an existing system may be tested with the system gas and must be checked with a leak detectant that does NOT contain which of these agents? - ANSWER -Ammonia a valve installed in each medical gas and vacuum piping system shall be tested to verify which of the following? - ANSWER -proper operation and rooms or areas of control

Show more Read less
Institution
Med Gas
Course
Med Gas

Content preview

Med Gas Study Guide Questions And
Answers Updated 2027
oxygen cylinders in use and in storage shall be prevented from reaching
temperatures in excess of how many degrees Fahrenheit? - ANSWER -125^o
degrees

non-mandated fundamentals and recommended guidelines for medical gas and
vacuum systems shall be located in the ________________ of the NFPA 99 code
of ASSE 6000 standards. - ANSWER -annexes or appendices

the level of sedation allowed for use in a category 2 dental health facility is limited
to which of the following? - ANSWER -moderate and minimal sedation

what is the standard gauge pressure (psi) for nitrogen gas service? - ANSWER -
55-185

in a category 1 health care facility, what is the maximum length (feet) allowed for
a nonmetalic flexible connector to connect to the manifold in a medical gas piping
system? - ANSWER -they shall be no longer than necessary

in compliance with NFPA 70, new wiring is installed underground form (from?)
the source to the junction box entering the building. what is the minimum number
of sets of wires to connect the initiating device with the junction box? - ANSWER
-1

which of the following fittings is NOT permitted for joining vacuum distribution
pipeline systems? - ANSWER -non-removable push-fit

medical air sources shall be sued (used ?) only for ________ and human
respiration - ANSWER -calibration of medical respiratory devices

,in central supply systems using gas cylinders, each header shall have a
__________ valve to prevent backflow and to permit service to the header. -
ANSWER -check

WAGD networks shall provide a WAGD inlet in all locations where __________
is intended to be administered. - ANSWER -nitrous oxide

which is a permitted use of the medical-surgical vacuum system? - ANSWER -
waste anesthetic gas disposal

which of the following is an instrument air quality requirement? - ANSWER -it
shall be compliant with Instrument Air section ANSI/ISA S-7 0.01

Riser valves are those valves located where? - ANSWER -in the riser adjacent to
the main line

all positive-pressure supply systems shall be provided with means to control the
final line pressure at the source and include _________. - ANSWER -all of the
above: controls that are able to provide 100 percent capacity & protection against
overpressure & the ability to service or replace components while maintaining
normal operation

during a patient emergency, when NFPA 99 code may be superseded by
__________ actions shall be reviewed and documented for future events. -
ANSWER -a medical professional

when an installer installs products or devices not designated by code, items shall
have supporting technical documentation approved by which of the following? -
ANSWER -AHJ

Prior to the installation of a manufactured assembly, documentation shall be
provided for all EXCEPT which of the following tests? - ANSWER -cross
connection

, installers shall have documentation indicating which of the following piping
materials have been certified for use in a medical gas distribution system? -
ANSWER -ASTM B819 hard drawn copper tube

maintenance of which of the following on site, supporting documentation is
required of a medical gas installer? - ANSWER -brazing qualification and
procedure

a medical air portioning system shall have a minimum of how many recorders in
order to record system performance and air quality for a period of no less than 24
hours? - ANSWER -1

a wireless communication device is employed in a medical gas or vacuum warning
system. which type of supervision is required for this device? - ANSWER -the
device will be supervised such that failure of communication shall initiate an alarm

the removal of components with a source system for repair and re-installation or
for replacement shall be treated as new work for the purposes of testing whenever
such work involves which of the following? - ANSWER -cutting and/or brazing
new piping

category 2 Dental Gas and Vacuum Systems require documentation for the
installation which of the following? - ANSWER -oxygen and nitrous oxide

category 1 facility, which of the following item(s) is correct regarding the standing
vacuum test for vacuum piping? - ANSWER -during the test the source of the test
vacuum shall be disconnected from the piping system

the final connection between new piping and an existing system may be tested
with the system gas and must be checked with a leak detectant that does NOT
contain which of these agents? - ANSWER -Ammonia

a valve installed in each medical gas and vacuum piping system shall be tested to
verify which of the following? - ANSWER -proper operation and rooms or areas
of control

Written for

Institution
Med Gas
Course
Med Gas

Document information

Uploaded on
March 20, 2026
Number of pages
28
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$14.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamMaestro Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
149
Member since
2 year
Number of followers
5
Documents
3564
Last sold
1 week ago
STA

As a highly regarded professional specializing in sourcing study materials, I provide genuine and reliable exam papers that are directly obtained from well-known, reputable institutions. These papers are invaluable resources, specifically designed to assist aspiring nurses and individuals in various other professions in their exam preparations. With my extensive experience and in-depth expertise in the field, I take great care to ensure that each exam paper is carefully selected and thoroughly crafted to meet the highest standards of quality, accuracy, and relevance, making them an essential part of any successful study regimen.

Read more Read less
3.6

18 reviews

5
9
4
2
3
2
2
0
1
5

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions