Property and Building Inspection Module 1 with all
Correct & 100% Verified Answers |Latest Version |
Already Graded A+

The purpose of this code is to establish ____ requirements to safeguard the public safety, health and
general welfare ✔Correct Answer-minimum

Where, in any specific case, different section of this code specify different materials, methods of
construction or other requirements, the most ____ shall govern ✔Correct Answer-restrictive

Where a reference code or standard includes subject matter that is within the scope of the IRC, the
provision of the ____ shall take precedence ✔Correct Answer-IRC

Compliance with the specific ____-based provisions of the International Codes inline of specific
requirements of the IRC shall be permitted as an alternative ✔Correct Answer-performance

An alternative material or method shall be approved where the proposed design is ____ and
complies with the ____ of the code ✔Correct Answer-satisfactory / intent

A permit is not required for one-story detached accessory structure, provided that the floor area
does not exceed ____ square feet ✔Correct Answer-200 sqft

Fences that are ____ feet or less in height do not require permits ✔Correct Answer-7'

A permit is not required for the replacement of branch circuit overcurrent devices (breakers) of the
required capacity in the same location (within a panel) ✔Correct Answer-True

Unattached decks not exceeding ____ square feet in area, that are not more than ____ inches above
grade, do not require a permit ✔Correct Answer-200 sqft / 30"

Where equipment replacements and repairs must be performed in an emergency situation, the
permit application shall be submitted within the ___ ___ business day ✔Correct Answer-next
working

An application for a permit for any proposed work shall be deemed to have been abandoned ____
days after the date filing ✔Correct Answer-180 days

Before issuing a permit, the building official is ____ to examine or cause to be examined buildings,
structures and sites for which an application has been filed. ✔Correct Answer-authorized

Where the building official issues a permit, the construction documents shall be approved in writing
or by a stamp that states ____ ____ ____ ____ ✔Correct Answer-Review for Code Compliance

Final inspection shall be made after the permitted work is ____ and prior to ____. ✔Correct
Answer-complete / occupancy

If located in a flood hazard area, the documentation of elevations required in Section R322.1.10 shall
be submitted to the building official prior to the ____ inspection ✔Correct Answer-final

, Signifies access that requires the removal of an access panel or similar removable obstruction.
✔Correct Answer-Access (to)

A wall supporting any vertical load in addition to its own weight is a ____-____ wall. ✔Correct
Answer-load-bearing

A finished or unfinished habitable space within an attic. ✔Correct Answer-Attic, Habitable

How water is water at a temperature greater than or equal to ____F ✔Correct Answer-110 deg F

What is the minimum uniformly distributed live load for habitable attics and attics served with fixed
stairs? ✔Correct Answer-30lbs per sqft

Wood structure panels with a minimum thickness of ____ inches and a maximum span of ____ feet
shall be permitted for opening protection in windburn debris regions. ✔Correct Answer-7/16" / 8'

The seismic provision of the IRC apply to detached one- and two-family dwellings in Seismic Design
Categories ____. ✔Correct Answer-D0, D1 and D2

For dwellings with fire sprinkler systems, exterior walls with a fire separation distance less that ____
feet shall have not less than a 1-Hour fire resistance rating with exposure from the outside
✔Correct Answer-3'

In a nonsprinklered townhouse building, the common wall between units hall be a minimum ____-
hour ____-____ ____ wall assembly. ✔Correct Answer-2-hour fire resistance rated

For townhouse separation, a parapet is not required where the roof sheathing is fire-retardant-
treated wood for a distance of ____ feet on each side of the wall and there are not penetration in the
roof within ____ feet of the common wall ✔Correct Answer-4' / 4'

Openings from a private garage directly into a room used for ____ ____ shall not be permitted.
✔Correct Answer-sleeping purposes

Doors between the garage and residence shall be equipped with a ____-____ ____ ✔Correct
Answer-self-closing or automatic-closing device

Garages shall be separated from residences and attics by not less than ____-inch gypsum board or
equivalent applied to the garage side. ✔Correct Answer-1/2"

Enclosed space under stairs that is accessed by a door or access panel shall have walls, under-stair
surface and any soffits protected on the enclosed side with ____-inch gypsum board ✔Correct
Answer-1/2"

Wall and ceilings finishes shall have a flame spread index of not greater than ____. ✔Correct
Answer-200

In combustible construction, fire blocking shall be provided to cut off all concealed draft opening and
to form an effective fire barrier between ____. ✔Correct Answer-stories

Document information

Uploaded on
March 17, 2026
Number of pages
13
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Studyclub
3.6
(14)
Sold
69
Followers
1
Items
13395
Last sold
7 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions