_________ _________ shall be listed in accordance with UL 30 where used to increase the maximum
allowable quantities per control area in accordance with Table 5003.1.1(1). ✔Correct Answer-
Safety cans

_________ _________ shall not be used to clean or remove debris from piping open to the
atmosphere. ✔Correct Answer-Flammable gases

A bonfire shall not be conducted within _________ feet of a structure or combustible material unless
the fire is contained in a barbecue pit. ✔Correct Answer-50

A construction permit is required for a stationary storage battery system consisting of lead-acid
batteries with a capacity of _________ kWh or more. ✔Correct Answer-70

A corridor in a nonsprinklered building serving an occupant load of 440 must have a minimum width
of _________ inches. ✔Correct Answer-88

A manual actuation device shall be located at or near a means of egress from the cooking area not
less than _________ feet and not more than _________ feet from the kitchen exhaust system.
✔Correct Answer-10, 20

A manual fire alarm system is required in Group F occupancies which are_________ or more stories
in height and have an occupant load of _________ or more above or below the lowest level of exit
discharge. ✔Correct Answer-2, 500

A maximum of _________ occupants are permitted to be served by one exit in the first-story of a
Group S occupancy. ✔Correct Answer-29

A maximum of _________ percent of the exit access pathways can travel through a stockroom in a
Group M occupancy. ✔Correct Answer-50

A minimum clearance of _________ feet shall be maintained between automatic sprinklers and the
top of piles of combustible fibers. ✔Correct Answer-3

A sign shall be provided at each floor landing in an interior exit stairway and ramp connecting more
than _________ stories designating the floor level, the terminus of the top and bottom of the
interior exit stairway and ramp and the identification of the stairway or ramp. ✔Correct Answer-
three (3)

A standpipe is required in buildings which have _________ or more stories above or below grade
plane, or have a floor level located more than _________ feet above the lowest level of the fire
department vehicle access or below the highest level of fire department vehicle access. ✔Correct
Answer-4, 30

Above-ground tanks used for outdoor, above-grade storage of Class IIIB liquid motor fuel shall be
listed and labeled in accordance with _________ or listed and labeled in accordance with _________
and shall be installed in accordance with Chapter 57. ✔Correct Answer-UL 142, UL 2085

, Aircraft-fueling vehicles shall be provided and maintained with a substantial heavy-duty electrical
cable of sufficient length to be _________ to the aircraft to be serviced. ✔Correct Answer-bonded

Air-supported and air-inflated structures shall have the design and construction of the fabric
envelope and the method of anchoring in accordance with _________ _________ _________
_________ . ✔Correct Answer-Architectural Fabric Structures Institute

An activation test of the emergency lighting equipment shall be performed _________. ✔Correct
Answer-monthly

An approved _________ _________ _________ _________ designed to close in the event of a fire or
impact shall be properly installed in the liquid supply line at the base of each dispenser supplied by a
remote pump. ✔Correct Answer-automatic emergency

An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and
maintained for Group A occupancies, other than those occupancies used exclusively for purposes of
_________ _________ with an occupant load less than _________ and for buildings containing both
a Group A occupancy and an atrium. Group A occupancies shall comply with Sections 403.2.1
through 403.2.4. ✔Correct Answer-religious worship, 2000

An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared for
buildings with high-piled combustible storage where the high- piled storage area exceeds _______
square feet for Class I-IV commodities or _______ square feet for high-hazard commodities.
✔Correct Answer-500,000, 300,000

An automatic sprinkler system in a Group R-4, Condition 2 occupancy can be installed to which
standard? ✔Correct Answer-NFPA 13R or NFPA 13

An automatic sprinkler system shall not be required in Type III-B dry cleaning plants where the
aggregate quantity of Class III-B solvent in dry cleaning machines and storage does not exceed
_________ gallons. ✔Correct Answer-3300

An operational permit shall remain in effect until _________, _________ or _________, or for such a
period of time as specified in the permit. ✔Correct Answer-reissued, renewed, revoked

Any _________ or _________ buildings or structures determined to be unsafe pursuant to Section
114 of the IFC relating to structural or interior hazards shall be marked as required by Sections
311.5.1 through 311.5.5. ✔Correct Answer-vacant, abandoned

Approved access shall be provided and maintained for all fire protection system equipment to permit
_________ safe operation and maintenance of such equipment. ✔Correct Answer-immediate

Approved safeguards shall be provided to prevent a_________ - _________ _________ in a tank
from creating a hazardous condition, including but not limited to, overheating of a tank or its
contents. ✔Correct Answer-low-liquid level

Asphalt (tar) kettles shall not be located within _________ feet of any combustible material,
combustible building surface or any building opening. ✔Correct Answer-20

Document information

Uploaded on
March 17, 2026
Number of pages
10
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Stuvia2026
2.3
(3)
Sold
26
Followers
1
Items
6330
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions