The CCDS certification signifies that a healthcare professional has achieved a verified, high level of clinical judgment and knowledge in cardiac rhythm device therapy . The certification examination is designed to assess essential clinical knowledge relevant to both the implantation and the ongoing follow-up of pacemakers and implantable cardioverter-defibrillators (ICDs) . While the core competency is the same, IBHRE offers the certification under two distinct tracks to reflect different professional roles : Physician CCDS: Aimed at physicians and fellows-in-training who implant devices and manage patients with heart rhythm disorders . Allied Professional CCDS: Intended for a broad range of non-physician professionals involved in device management, patient follow-up, and industry support . This certification is accredited by the ANSI National Accreditation Board (ANAB), underscoring its adherence to rigorous international standards IBHRE CCDS/ TEST FINAL EXAM ACTUAL EXAM COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS) / ALREADY GRADED A+ What current ICD capacitor technologies provide the highest energy density and do not require reformation? - ANSWER-Tantalum Electrolytic 1.67 Hz would equal how many bpm? - ANSWER-100 bpm 1 bpm = 0.0166667 Hz Which pace/sense lead designs would one expect the highest current density w/ a bipolar impedance reading of 1100 ohms? - ANSWER-Brady lead w/ anode of 4.2 mm2 and cathode 5.2 mm2 What is the voltage measurement of a pacing system w/ impedance of 500 ohms, current of 5.0 milliamp and pulse width of 0.4 ms and rate of 60 bpm? - ANSWER-V = 2.5 V V=I x R = 5.0 milliamps x 500 ohms = 2,500 millivolts =2,500/1000 What condition is shown to have an increase stimulation threshold, wide QRS, latency, or under sensing? - ANSWER-Hyperkalemia (high potassium) What is the estimated battery longevity of a pacemaker with 1.0 amp-hour battery and 20 microamp drain - ANSWER-Longevity = 114 x (amp-hours/microamp drain) = 114 x (1.0/20) = 5.7 years

Show more Read less
Institution
IBHRE CCDS
Course
IBHRE CCDS

Content preview

IBHRE CCDS/ TEST FINAL EXAM ACTUAL
EXAM COMPLETE ACCURATE EXAM
QUESTIONS WITH DETAILED VERIFIED
ANSWERS (100% CORRECT ANSWERS) /
ALREADY GRADED A+

What current ICD capacitor technologies provide the highest energy density and do
not require reformation? - ANSWER-Tantalum Electrolytic

1.67 Hz would equal how many bpm? - ANSWER-100 bpm
1 bpm = 0.0166667 Hz

Which pace/sense lead designs would one expect the highest current density w/ a
bipolar impedance reading of 1100 ohms? - ANSWER-Brady lead w/ anode of 4.2
mm2 and cathode 5.2 mm2

What is the voltage measurement of a pacing system w/ impedance of 500 ohms,
current of 5.0 milliamp and pulse width of 0.4 ms and rate of 60 bpm? -
ANSWER-V = 2.5 V

V=I x R
= 5.0 milliamps x 500 ohms
= 2,500 millivolts
=2,500/1000

What condition is shown to have an increase stimulation threshold, wide QRS,
latency, or under sensing? - ANSWER-Hyperkalemia (high potassium)

What is the estimated battery longevity of a pacemaker with 1.0 amp-hour battery
and 20 microamp drain - ANSWER-Longevity = 114 x (amp-hours/microamp
drain)
= 114 x (1.0/20)
= 5.7 years

,Which sensing related parameter represents the maximal rate of change of the
electrical potential between the sensing electrode and is the first derivative of the
electrogram? - ANSWER-Slew rate

The isovolumetric time from electrical depolarization of the heart to mechanical
systole describes what term? - ANSWER-Pre-ejection interval

What test is typically performed during exercise with HR around 105-115 and was
shown to have a negative predictive value in MADIT II and SCD-HeFT? -
ANSWER-Micro volt t-wave alternans

Which battery chemistry is now incorporated into pacemakers? - ANSWER-
Lithium silver vanadium & lithium carbon mono fluoride

What test is performed over 10-20 beats following a PVC and whose absence is a
predictor of cardiac mortality following an MI? - ANSWER-Micro volt t-wave
alternans

Fluoroquinolones, a new gen antibiotic is known for which cardiac effect? -
ANSWER-Prolonging QT

What would decrease stim thresholds and current drain? - ANSWER-Reducing
electrode surface area
Ex: from 12mm to 8mm

Match the units: watt-second - ANSWER-Power

Defibrillation energies exceed pacing energies by a factor of? - ANSWER-
1,000,000

A band-pass filter modifies incoming signals according to which of the following
units of measure? - ANSWER-Hertz

AV block occurs in what percentage of congenital open-heart surgeries? -
ANSWER-1-3%

,In order to have a pacing system automatically assess capture and thresholds, the
essential electrode characteristics would be? - ANSWER-Minimal electrode
diameter size

In a normal person, stroke volume increases by what % when exercising? -
ANSWER-50%

In pacing, capacitors are: - ANSWER-Charged in parallel and discharged in series

In a circuit with resistance of 500 ohms and 600 ohms in the parallel circuit the
resistance would be? - ANSWER-R total = R1 x R2
————
(R1 + R2)
= (500 x 600)
——————-
(500 + 600)
= 272.7 ohms

Battery capacity of a pacemaker is given in which parameter? - ANSWER-Current

Most commonly utilized battery in current ICDs? - ANSWER-Lithium silver
vanadium oxide

What does one French size equal in mm? - ANSWER-0.3mm

What drug will increase DFT within 2 days? - ANSWER-Flecainide

What drug might be given to reduce pacing thresholds? - ANSWER-Isoproterenol
IV

Which pacing indication would most likely use Rate drop response, sudden Brady
response or rate hysteresis? - ANSWER-Carotid sinus hypersensitivity

What was a secondary endpoint finding CTOPP and MOST studies comparing
atrial vs ventricle pacing? - ANSWER-Reduced onset of AF

, Patient with long QT getting ICD. What drug should be avoided due to increased
risk of Torsades De Pointes - ANSWER-Erythromycin

What drug may reduce digoxin clearance by 30% resulting in the need to reduce
digoxin dose and retitrate based on serum levels? - ANSWER-Amiodarone

What drug may significantly lower myocardial stimulation thresholds? -
ANSWER-Verapamil

Proper lead position in a child who has undergone a Fontan procedure? -
ANSWER-Epicardial V lead, with subsequent transvenous A lead

What causes cardiac C fibers in patients exhibiting vasodepressor syncope? -
ANSWER-Vigorous squeezing of relatively empty ventricles

Approximate infection rate of CRTD implant in a normal healthy male? -
ANSWER-2-4%

Lead extraction morbidity and mortality rate? - ANSWER-1-3%

What is the normal range of PCWP? - ANSWER-4-12 mm/Hg

What is the most dangerous interaction between RF ablation and pacemakers? -
ANSWER-Runaway pacing

Most common reason for ICD classifies false VT/VF? - ANSWER-EMI

Which of the following is a Class III indication for ICD implant?
- VT not due to reversible cause
- severely symptomatic VT while patient awaits transplant
- Incessant VT
- NSVT, previous MI, positive EP Study - ANSWER-VT not due to reversible
cause

An EP takes a retrospective look at 360 consecutive ICD patients to gather data
one his patient survival statistic. It uncovers one pharmacological factor was linked
to better patient survival, what is it? - ANSWER-Beta blocker therapy

Written for

Institution
IBHRE CCDS
Course
IBHRE CCDS

Document information

Uploaded on
March 7, 2026
Number of pages
113
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$18.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
GradeBooster7

Get to know the seller

Seller avatar
GradeBooster7 Chamberlain College Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
2 months
Number of followers
0
Documents
179
Last sold
7 hours ago
ScoreLab

Welcome to your go-to destination for reliable, high-quality exam and study resources designed to help students succeed with confidence. Our store offers carefully curated exam materials, practice questions, summaries, and study guides created to align with real course content and academic standards. Each resource is developed with a strong focus on accuracy, clarity, and exam relevance, making it ideal for students who want to study smarter—not longer. Whether you’re preparing for quizzes, midterms, finals, or professional exams, our materials are structured to reinforce key concepts, improve understanding, and boost exam performance. We prioritize well-organized content, clear explanations, and up-to-date material, ensuring you get resources you can trust. Thousands of students rely on quality preparation to achieve better results—this store is built to support that goal. Study with confidence. Prepare with purpose. Succeed in your exams.

Read more Read less
0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions