ASRT modules review EXAM QUESTIONS AND VERIFIED ANSWERS | 100% CORRECT | GRADED A+ | GUARANTEED SUCCESS. Helical scanning motion was first made possible by the unique construction of the ____________ scanner. A) fourth generation B) fifth generation C) sixth generation D) seventh generation - ANSWER7th The type of beam geometry used in modern CT scanners is called: A) fan beam. B) wide beam. C) pencil beam. D) cone beam. - ANSWERcone beam Which of the following is not a component of the CT gantry? A) X-ray tube B) Array processor C) Slip rings D) Digital acquisition system - ANSWERarray processor Detector systems in which the elements are not all the same size are referred to as: A) adaptive arrays. B) volumetric arrays. C) symmetric arrays. D) unbalanced arrays. - ANSWERadaptive arrays The ___________ method of data acquisition gathers image data in distinct sections and is sometimes describes as having a "start/stop" motion. A) spiral B) sequential C) helical D) volume - ANSWERsequential When pitch is less than 1, the resulting bands of data are: A) adjacent. B) distinct. C) overlapped. D) gapped - ANSWERoverlapping All of the following are characteristics of beam-shaping filters, except: A) they are physical devices. B) they change the spatial distribution of the beam. C) they change the digital appearance of images. D)they remove lower-energy x-rays from the beam. - ANSWERthey change digital appearance of images The primary data processing component of the CT system is the: A) array processor. B) digital acquisition system. C) PACS. D) amplifier. - ANSWERarray processor An increase in pitch also results in increased: A) patient dose. B) scan speed. C) image quality. D) scan length. - ANSWERscan speed Which component of the CT gantry supplies electrical power to the x-ray tube and transfers the signals from the detectors to the computer? A) Generator B) Slip rings C) Photomultiplier D) Data acquisition system - ANSWERslip rings The first generation CT scan pattern was called _______ acquisition. A) translate and rotate B) step-and-shoot C) helical D) linear - ANSWERtranslate and rotate The largest piece of the CT device is called: A) the gantry. B) the processor. C) the housing. D) the ring. - ANSWERgantry When considering detector efficiency, the measure of how consistently the detectors respond is called: A) capture efficiency. B) absorption efficiency. C) stability. D) response time. - ANSWERstability Which of the following is false regarding conventional axial scanning compared to helical scanning? A) Axial scanning requires more contrast media. B) Axial scanning has greater potential for misalignment between scans. C) Axial scanning is more sensitive to patient motion. D) Axial scanning results in poorer image quality. - ANSWERmore sensitive to patient motion The number of detectors the scanner uses to collect data for a particular scan is

Content preview

SRT modules review EXAM QUESTIONS AND VERIFIED
ANSWERS | 100% CORRECT | GRADED A+ | GUARANTEED
SUCCESS.




Helical scanning motion was first made possible by the unique construction of
the ____________ scanner.
A) fourth generation B) fifth generation C) sixth generation D) seventh
generation - ANSWER>>7th

The type of beam geometry used in modern CT scanners is called:
A) fan beam. B) wide beam. C) pencil beam. D) cone beam. - ANSWER>>cone
beam

Which of the following is not a component of the CT gantry?
A) X-ray tube B) Array processor C) Slip rings D) Digital acquisition system -
ANSWER>>array processor

Detector systems in which the elements are not all the same size are referred to
as:
A) adaptive arrays. B) volumetric arrays. C) symmetric arrays. D) unbalanced
arrays. - ANSWER>>adaptive arrays

The ___________ method of data acquisition gathers image data in distinct
sections and is sometimes describes as having a "start/stop" motion.
A) spiral B) sequential C) helical D) volume - ANSWER>>sequential

When pitch is less than 1, the resulting bands of data are:
A) adjacent. B) distinct. C) overlapped. D) gapped - ANSWER>>overlapping

,All of the following are characteristics of beam-shaping filters, except: A)
they are physical devices.
B) they change the spatial distribution of the beam.
C) they change the digital appearance of images.
D) they remove lower-energy x-rays from the beam. - ANSWER>>they change
digital appearance of images

The primary data processing component of the CT system is the:
A) array processor. B) digital acquisition system. C) PACS. D) amplifier. -
ANSWER>>array processor

An increase in pitch also results in increased:
A) patient dose. B) scan speed. C) image quality. D) scan length. -
ANSWER>>scan speed

Which component of the CT gantry supplies electrical power to the x-ray tube
and transfers the signals from the detectors to the computer?
A) Generator B) Slip rings C) Photomultiplier D) Data acquisition system -
ANSWER>>slip rings

The first generation CT scan pattern was called _______ acquisition.
A) translate and rotate B) step-and-shoot C) helical D) linear -
ANSWER>>translate and rotate

The largest piece of the CT device is called:
A) the gantry. B) the processor. C) the housing. D) the ring. - ANSWER>>gantry

When considering detector efficiency, the measure of how consistently the
detectors respond is called:
A) capture efficiency. B) absorption efficiency. C) stability. D) response time. -
ANSWER>>stability

, Which of the following is false regarding conventional axial scanning compared
to helical scanning?
A) Axial scanning requires more contrast media.
B) Axial scanning has greater potential for misalignment between scans.
C) Axial scanning is more sensitive to patient motion.
D) Axial scanning results in poorer image quality. - ANSWER>>more sensitive to
patient motion

The number of detectors the scanner uses to collect data for a particular scan is
determined by the:
A) scan field of view. B) display field of view. C) pitch. D) slice thickness. -
ANSWER>>SFOV



All of the following types of exams typically use a large SFOV, except for:
A) chest exams. B) spine exams. C) extremity exams. D) skull exams. -
ANSWER>>skull

Matrix size never changes, but the pixel size can vary based on the selected: A)
scan field of view. B) pitch. C) kVp. D) mAs. - ANSWER>>SFOV

The element of a photomultiplier tube that converts the initial pulse of light to
electrons is the: '
A) semiconductor. B) photocathode. C) dynode. D) scintillator. -
ANSWER>>photocathode

The ability of a detector to produce the same output given the same input is
called its: A) reproducibility. B) efficiency. C) stability. D) dynamic range. -
ANSWER>>reproducibility

Compared to helical scanning, axial scanning is associated with reduced:

Document information

Uploaded on
February 22, 2026
Number of pages
22
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ExcelAcademia2026
3.7
(385)
Sold
2284
Followers
1650
Items
9018
Last sold
3 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions