The FDA has recommended that extended wear contact lenses be worn for a maximum
of:

a. 7 days
b. 14 days
c. 30 days
d. 45 days - Answer- a. 7 days

The CPC of a rigid lens was ordered 7.84mm and was received measuring 7.94mm.
This lens is _____ than ordered.

a. 0.50D steeper
b. 1.00D flatter
c. 0.50 flatter
d. 1.00D steeper - Answer- c. 0.50 flatter

When comparing high DK silicone acrylate polymers to earlier generation materials of
the same type, the new "improved" silicone acrylates

1 increase oxygen permeability
2 flex less
3 have poorer wetting characteristics
4 scratch less

a. 1 only
b. 1 and 3
c. 2 and 4
d. all are correct - Answer- b. 1 and 3

A normal fitting soft contact lens will have:

a. three point touch (apex and periphery)
b. apical clearance

,c. edge stand-off
d. none of the above - Answer- a. three point touch (apex and periphery)

Therapeutic soft lenses should be fit with minimal movement in which case?

a. Keratitis sicca
b. Trichiasis
c. Recurrent erosion
d. Keratoconus - Answer- c. Recurrent erosion

An aphakic patient with K readings of 40.50 @ 180/41.25 @ 90, large palpebral fissures
and flaccid lower lids is a good candidate for

a. a one cut
b. a myoflange lenticular
c. a hyperflange lenticular
d. a back toric - Answer- b. a myoflange lenticular

When evaluating fluorescein patterns, a special filter must be used with __________.

a. Silicone acrylate
b. Polymethylmethacrylate
c. Fluropolymers
d. Hydroxyethyl methacrylate - Answer- c. Fluropolymers

The keratometer is an instrument used to measure

a. Corneal curvature
b. Lens power
c. Lens diameter
d. Lens thickness - Answer- a. Corneal curvature

A lens fitted for keratoconus should:

a. Flatten the apex
b. Ride high
c. Align the apex
d. Ride low - Answer- c. Align the apex

A soft contact lens which is too loose can show all the following EXCEPT:

a. edge stand-off
b. limbal compression
c. a bubble under the lens edge
d. clear retinoscopy directly after blinking - Answer- b. limbal compression

, Correction of a high riding rigid minus lens is accomplished by using a

a. Flatter lens
b. Larger lens
c. Minus carrier lenticular lens
d. Prism lens - Answer- d. Prism lens


Assessment of the quality of the peripheral curves (blends of a rigid contact lens) is
achieved by the use of the-
a. profile analyzer
b. shadow graph
c. keratometer
d. burton light - Answer- a. profile analyzer

Contact lens power should be specified in-
a. back vertex power
b. sphero-cylinder power
c. power in situ
d. posterier apical radius - Answer- a. back vertex power

The slit-lamp illumination that gives an overall view of the cornea but limits detail is-
a. sclerotic scatter
b. diffuse
c. specular reflection
d. oscilatory - Answer- b. diffuse

When a keratometric miers reflected off a soft contact lens are only clear when the
wearer blinks, the lens fit is too-
a. small
b. large
c. steep
d. flat - Answer- c. steep

Transient keratometric mier distortion is usually due to-
a. pre-ocular tear film abnormalities
b. prolonged rigid lens wear
c. prolonged soft lens wear
d. irregular corneal astigmatism - Answer- a. pre-ocular tear film abnormalities

Epithelial edema which manifests itself clinically as central corneal haze, is verified by
the slit lamp using sclerotic scatter illumination. What specific technique does the
examiner use to see this condition?
a. the naked eye and an angle between the slit lamp beam and the eye of 90˚
b. the blue cobalt filter of the slit lamp and an angle of about 45˚
c. the green filter of the slit lamp with high magnification

Document information

Uploaded on
February 19, 2026
Number of pages
16
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Scholarsstudyguide
3.8
(169)
Sold
846
Followers
476
Items
16355
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions