Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 3 out of 16 pages
Exam (elaborations)

NCLE TEST QUESTIONS WITH VERIFIED ACCURATE ANSWERS LATEST UPDATED

Document preview thumbnail
Preview 3 out of 16 pages

NCLE TEST QUESTIONS WITH VERIFIED ACCURATE ANSWERS LATEST UPDATED

Content preview

NCLE TEST | QUESTIONS WITH VERIFIED ACCURATE
ANSWERS | LATEST UPDATED

Assessment of the quality of the peripheral curves (blends of a rigid contact lens) is
achieved by the use of the-
a. profile analyzer
b. shadow graph
c. keratometer
d. burton light - Answers -a. profile analyzer

Contact lens power should be specified in-
a. back vertex power
b. sphero-cylinder power
c. power in situ
d. posterier apical radius - Answers -a. back vertex power

The slit-lamp illumination that gives an overall view of the cornea but limits detail is-
a. sclerotic scatter
b. diffuse
c. specular reflection
d. oscilatory - Answers -b. diffuse

When a keratometric miers reflected off a soft contact lens are only clear when the
wearer blinks, the lens fit is too-
a. small
b. large
c. steep
d. flat - Answers -c. steep

Transient keratometric mier distortion is usually due to-
a. pre-ocular tear film abnormalities
b. prolonged rigid lens wear
c. prolonged soft lens wear
d. irregular corneal astigmatism - Answers -a. pre-ocular tear film abnormalities

Epithelial edema which manifests itself clinically as central corneal haze, is verified by
the slit lamp using sclerotic scatter illumination. What specific technique does the
examiner use to see this condition?
a. the naked eye and an angle between the slit lamp beam and the eye of 90˚
b. the blue cobalt filter of the slit lamp and an angle of about 45˚
c. the green filter of the slit lamp with high magnification
d. high magnification and an angle between the beam and scope of 180˚ - Answers -a.
the naked eye and an angle between the slit lamp beam and the eye of 90˚

,With a rigid contact lens in place a flourescein pattern shows a narrow bend horizontally
wih a concentration of flourescein inferiorly and superiorly under the lens. Which one of
the following type of astigmatism is represented by this pattern?
a. lenticular astigmatism
b. residual astigmatism
c. against the rule astigmatism
d. with the rule astigmatism - Answers -d. with the rule astigmatism

Refractive Rx -3.00 -1.00 x 170
K's 42.00 @ 170/43.00 @ 80
Given the above Rx and K's he following diagnostic toric soft lens was used:
B.C. 8.8
Power -3.00 -1.00 x 180
During dianostic evalutation, the above lens rotated 10 clockwise. The lens ordered
should have an axis of:
a. 10
b. 180
c. 170
d. 160 - Answers -b. 180

Given the same circumstances from the above question, once the correctly ordered lens
has been dispensed, the rotational marks should settle at _______.
a. 6 o clock
b. 10 clockwise rotation
c. 10 counter clockwise rotation
d. none of the above - Answers -b. 10 clockwise rotation

An instrument that allows simultaneous verification of lens diameter, optic zone width,
and peripheral curve width is:
a. measuring magnifier
b. ophthalmometer
c. profile analyzer
d. radiuscope - Answers -a. measuring magnifier
(the book says d. radiuscope)

The instrument used for magnification of the edge of a rigid CL is a _______.
a. radiuscope
b. shadowgraph
c. profile analysis
d. keratometer - Answers -b. shadowgraph

Mary is wearing in her right eye RGP lens with a base curve of 43.50 and a power of
+2.75. The doctor refracts -0.75 sphere over this lens. If you wish to order her a new
lens with a curve of 43.00, what will the new power be?
a. +1.50
b. +2.00

, c. +2.50
d. +3.00 - Answers -c. +250

Which of the following could be considered in the fitting of a keratoconus patient
1. aspheric
2. McGuire
3. Soper
4. tangent streak

a. 1 & 2
b. 2 & 3
c. 3 & 4
d. 1, 2 and 3 - Answers -d. 1, 2 and 3

Two designs helpful in orienting high riding myopic lenses are:
1. flattening the B.C. relationship
2. myo-flang
3. hyper-flang
4. prism ballast

a. 1 & 2
b. 1 & 3
c. 2 & 3
d. 3 & 4 - Answers -d. 3 & 4

Age/related signs of presbyopia include:
1. tear film abnormalities
2. reduce lid elasticity
3. lens opacities
4. pupil constriction

a. 1 only
b. 1 & 3
c. 2 & 4
d. all of the above - Answers -d. all of the above

A good example of a bifocal contact lens which may rotate without vision imparement is:
a. aspheric
b. executive
c. fused crescent
d. tangent streak - Answers -d. tangent streak

Keratoconus and penetrating keratoplasty fittings are best accomplished by which of the
following methods?
a. nomogram
b. Ks and Rx

Document information

Uploaded on
February 18, 2026
Number of pages
16
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GEEKA
3.8
(366)
Sold
2157
Followers
1449
Items
60264
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions