100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Med gas Refresher Exam Questions and Answers|| GRADED A+|| LATEST UPDATE 2026

Rating
-
Sold
-
Pages
48
Grade
A+
Uploaded on
01-02-2026
Written in
2025/2026

Med gas Refresher Exam Questions and Answers|| GRADED A+|| LATEST UPDATE 2026

Institution
Med Gas Refresher
Course
Med gas Refresher











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Med gas Refresher
Course
Med gas Refresher

Document information

Uploaded on
February 1, 2026
Number of pages
48
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Med gas Refresher Exam Questions and
Answers|| GRADED A+|| LATEST UPDATE
2026


WAGD networks shall provide a WAGD inlet in all locations where __________ is

intended to be administered.

a. Nitrogen

b. Medical Air

c. Nitrous Oxide

d. Oxygen

c. Nitrous Oxide

Audible and visual alarm indicators shall meet which of the following

requirements?

a. Individual indicators shall NOT be less than DN20 size

b. Testing to determine indicator function should be scheduled periodically and

records maintained between testing.

c. CGA C-7

d. The staff should be trained to operate the test button periodically and report

malfunctions.

b. Testing to determine indicator function should be scheduled periodically and records

maintained between testing.

,Only one service valve is required for each branch off the riser, unless the

number of zone valves on that branch exceeds ______ valves.

a. 6

b. 8

c. there is no maximum

d. 4

c. there is no maximum

Which of the following systems shall not be permitted to be located in an outdoor

enclosure?

a. Bulk cryogenic liquid systems

b. Manifolds for gas cylinders

c. Manifolds for cryogenic liquid containers

d. Medical air compressor sources

d. Medical air compressor sources

NFPA 99 requires tubing to be cut square using a sharp tubing cutter that shall be

free from grease, oil or other lubricants not suitable for oxygen service. What sort

of treatment is permitted of the tube ends before brazing?

a. May be reamed

b. May be deburred or rolled smooth

c. May be re-cleaned

d. none of the above

b. May be deburred or rolled smooth

,Excluding outdoor locations, which of these is an NFPA 99 requirement for the

wiring of each of the two mandatory master alarms?

a.Common conductors

b.Without any splices

c.Wired independently to the initiating device(s) for each signal

d.Alarms shall be sent to the area alarm panel in the emergency room

c. Wired independently to the initiating device(s) for each signal

Inspection and testing shall be performed on all new piped gas systems,

additions, renovations, temporary installations or repaired systems to assure the

facility that all applicable provisions of NFPA 99C have been adhered to and

system integrity has been achieved or maintained. What is required of the

individual doing the testing or inspecting?

a.Have two years experience

b.Have a documented procedure

c.Be a certified tester

d.none of the above

b. Have a documented procedure

With the approval of the authority having jurisdiction, in what areas shall the

shutoff valves be permitted to be secured to prevent inappropriate access?

a.critical care

b.psychiatric or pediatric

c.maternity

d.anesthetizing

, b. psychiatric or pediatric

For purposes of this code, an oxygen enriched atmosphere is an atmosphere

where to total concentration of oxygen exceeds _______ by volume.

a.23.5%

b.23.6%

c.19.5%

d.93%

a.23.5%

Compressed gas cylinders must meet which of the following criteria in order to

be acceptable for use in an acute health care facility?

a.Be appropriately identified by labels or stencils in accordance with CGA C-7

criteria

b.Be appropriately color coded in accordance with U.S.D.A. requirements

c.Be constructed in accordance with specifications and regulations of OSHA

d.Utilize gas specific CGA connections

a. Be appropriately identified by labels or stencils in accordance with CGA C-7 criteria

In those portions of the system intended to handle oxygen at pressures greater

than 350 psi, the interconnecting hose shall not contain __________ materials.

a.stainless steel

b.polymeric

c.copper

d.brass

b. polymeric

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SimoDocs Chamberlain College Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
188
Member since
1 year
Number of followers
5
Documents
2357
Last sold
2 days ago

4.1

9 reviews

5
5
4
2
3
1
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions