• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 14 pages
Exam (elaborations)

Fresenius Final Exam QUESTIONS AND ANSWERS 100% RATED CORRECT WITH 100% SURE PASS|GRADED A+

Document preview thumbnail
Preview 2 out of 14 pages

Fresenius Final Exam QUESTIONS AND ANSWERS 100% RATED CORRECT WITH 100% SURE PASS|GRADED A+

Content preview

Fresenius Final Exam QUESTIONS AND
ANSWERS 100% RATED CORRECT
WITH 100% SURE PASS|GRADED A+
40-60 seconds - CORRECT ANSWERS How long to hand wash with soap and water?

20-30 seconds - CORRECT ANSWERS How long must you rub your hands with hand sanitizer?

Diabetes - CORRECT ANSWERS The number one cause for chronic renal failure

True - CORRECT ANSWERS When going from a dirty area to retrieve supplies in a clean area,
staff are required to complete hand hygiene

True - CORRECT ANSWERS HMIS (Hazardous Material Identification System) labels are
required on all hazardous materials, including individual bicarbonate containers

1 part bleach: 10 part water solution - CORRECT ANSWERS The first bleach solution used to
clean a large blood spill area (greater than 10mL/s) is

Infected blood and bodily fluids - CORRECT ANSWERS The main route of transmission of Hep
B in Hemodialysis facilities is by exposure to

Remove gloves, sanitize hands, and put on a fresh pair of gloves before - CORRECT ANSWERS
When caring for a patient who is Hep B positive, after disconnecting the bloodlines, the technician must
perform which 3 actions before documenting?

Separate area on a dedicated machine - CORRECT ANSWERS Patients who are Hep B surgace
Antigen positive should be dialyzed in a

Remove gloves, wash/sanitize hands, and retrieve items - CORRECT ANSWERS What must a
tech do prior to leaving the patient at the dialysis station to get clean supplies?

Remove gloves, wash/sanitize hands - CORRECT ANSWERS The tech has performed
rinseback on a patient and failed to gather all the supplies needed to disconnect the patient. What must
the tech do prior to getting supplies?

Blood splatter - CORRECT ANSWERS You must wear a full-face shield, or mask with goggles
when in an area with a risk of

Ultrapure Dialysate - CORRECT ANSWERS Use of a diasafe filter allows the production of

Conductivity - CORRECT ANSWERS the ability of a substance to conduct an electrical charge

Normal Saline - CORRECT ANSWERS Used to rinse and prime the tubing of the
extracorporeal circuit to remove sterilant and air

, Clotting - CORRECT ANSWERS Air is removed from the extracorporeal circuit before initiating
treatment because it may cause

bloodlines in the prime bucket with open end caps - CORRECT ANSWERS The most likely
cause of contamination of the extracorporeal circuit are

Air - CORRECT ANSWERS A low level arterial drip chamber can result in ______ entering the
system causing an air embolism or clotting

Conductivity - CORRECT ANSWERS Ability of a substance to conduct an electrical charge

Blood leak - CORRECT ANSWERS When blood escapes from the dialyzer blood compartment
into the dialysate fluid compartment

6.9-7.6 - CORRECT ANSWERS The final dialysate must have a ph between

Daily - CORRECT ANSWERS How often should staff clean the dialysis machine with acid?

Before each treatment - CORRECT ANSWERS When should alarm and Pressure Holding Tests
(PHT) should be performed on dialysis machines?

Air in the dialyzer - CORRECT ANSWERS What is removed by NS during the priming process?

+/-0.5mS of Theoretical Conductivity - CORRECT ANSWERS Before the start of treatment,
check that the machine's conductivity alarm parameters are set at

after cleaning with acid - CORRECT ANSWERS You should disinfect the dialysis machine with
heat after doing what?

Bacteria, Conductivity, Chlorine/Chloramines and pH - CORRECT ANSWERS You should test
the dialysate for these four things before starting treatment

The machine was in bypass for 30 min - CORRECT ANSWERS The wall clock indicates the
patient has had 3 hours of treatment and the machine indicates only 2.5 hours treatment. What
happened?

Kidneys to Ureters to Bladder to Urethra - CORRECT ANSWERS Flow of urine

Pressure difference across the dialyzer membrane - CORRECT ANSWERS The TMP
(Transmembrane Pressure) measures the

Diffusion - CORRECT ANSWERS Movement of particles from a greater to a lesser
concentration

Osmosis - CORRECT ANSWERS Movement of fluid from a low solute concentration to an
area of high concentration

pressure - CORRECT ANSWERS a major factor affecting ultrafiltration is

Document information

Uploaded on
January 27, 2026
Number of pages
14
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
12
Followers
5
Items
2564
Last sold
4 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions