• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 15 pages
Case

ICC REINFORCED CONCRETE final code test- Exam 60QUESTIONS AND ANSWERS 100% RATED CORRECT WITH 100% SURE PASS|GRADED A+

Document preview thumbnail
Preview 2 out of 15 pages

ICC REINFORCED CONCRETE final code test- Exam 60QUESTIONS AND ANSWERS 100% RATED CORRECT WITH 100% SURE PASS|GRADED A+

Content preview

ICC REINFORCED CONCRETE final
code test- Exam 60QUESTIONS AND
ANSWERS 100% RATED CORRECT
WITH 100% SURE PASS|GRADED A+
An acceptable reinforcing steel support mechanism for a 24-inch deep footing are?

-precast dobie blocks

-large,solid pieces of glass

-masonry CMU pieces

-wooden blocks - CORRECT ANSWERS Precast dobie blocks



all of the following are true except ?

---Minimum concrete cover for bundled bars of any size need not be greater than 2 inches, unless they
are in a member that's permanently cast against earth

---specified concrete cover for headed shear stud reinforcement shall not be less then the cover
requirement for the member in which the stud reinforcement is located

---Concrete cover for the flexural members, walls, and compression members with an effective depth of
8-inches can vary -3/8 of an inch

---Concrete cover for members in highly corrosive environments will typically remain the same as cast
against earth - CORRECT ANSWERS Concrete cover for members in highly corrosive
environments will typically remain the same as cast agonist earth



As a general rule, Lap splicing bar larger then NO.11 Is?

-not permitted

-permitted

-permitted if bars will be in tension within the structural member

-permitted only if bars are within a bundle - CORRECT ANSWERS not permitted

, before new concrete is placed, construction joints must be?

-blown free of dirt and debris

-wetted ,and standing water removed

-sand blasted

- treated with a bonding agent - CORRECT ANSWERS wetted, and standing water removed



grade 60 reinforcing steel has an ultimate strength of?

-60,000

-75,000

-90,000

-100,000 - CORRECT ANSWERS 90,000 psi



The__________may waive requirements for the employment of a special inspection agency if he/she
finds that the construction is of minor nature.

-building official

-engineer or architect of record

-owner

-all of the above - CORRECT ANSWERS building official



what is the maximum allowable center to center spacing of spliced bars in a non-contact lap splice for
the flexural members?

-6 inches

-4 inches

-8 inches

-2 inches - CORRECT ANSWERS 6 inches

Document information

Uploaded on
January 23, 2026
Number of pages
15
Written in
2025/2026
Type
Case
Professor(s)
N
Grade
A+
$14.79

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
12
Followers
5
Items
2564
Last sold
4 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions