Guaranteed Pass
The typical time required to heat a fluidized bed to ignition temperature prior to
the introduction of coal is:
Select one:
a. Two hours
b. Three hours
c. One hour
d. 30 minutes - CORRECT ANSWER✔✔C
When welding thick materials, proper weld groove selection and preparation
allows for:
Select one:
a. a quick weld
b. proper heat treatment
c. full penetration
d. omitting the root pass - CORRECT ANSWER✔✔C
An interrupted pilot of an automatic boiler:
Select one:
a. Ignites, is proven stable and extinguishes after the main flame is established
b. Is one that has been extinguished by an inadequate flame signal
,c. Ignites before the main burner ignites, and is extinguished when the main
burner is extinguished
d. Burns continuously, like that in a home furnace - CORRECT ANSWER✔✔A
In a fluidized bed boiler, a gradual loss of the fluidized bed, including fuel (carbon)
particles, is due to:
Select one:
a. Priming
b. Sootblowing
c. Uplift
d. Carryover - CORRECT ANSWER✔✔D
The test material for a penetrant test (PT) must be:
Select one:
a. ferrous
b. non-ferrous
c. porous
d. non-porous - CORRECT ANSWER✔✔D
If your plant maintenance department neglects oil changes, filter replacement,
and bearing lubrication, your plant will eventually need more unscheduled
___________ maintenance.
Select one:
a. Emergency
b. Preventative
,c. Routine
d. Project - CORRECT ANSWER✔✔A
The holder of a Certificate of Competency, the classification of which authorises
him or her to act as a engineer, may sketch, construct, install, operate, repair, and
give advice on all things pertaining to any _____ in which that person is
employed.
Select one:
a. Welding shop
b. Power plant
c. Fish plant
d. Hydro plant - CORRECT ANSWER✔✔B
Which of the following is a single pass boiler?
Select one:
a. HRT
b. Scotch marine
c. Packaged firetube
d. Vertical firetube - CORRECT ANSWER✔✔D
Iron and steel may be magnetized by rubbing the metal with a:
Select one:
a. Stainless steel
b. Steel wool
c. Brass rod
, d. Magnet - CORRECT ANSWER✔✔D
The apparatus which converts current signals to pneumatic and pneumatic to
current signals is called a:
Select one:
a. Transformer
b. Inverter
c. Transducer
d. Converter - CORRECT ANSWER✔✔C
Before a steam or air atomizing oil burner is removed from a boiler furnace, the
burner should be blown out with:
Select one:
a. Steam or air
b. High temperature solvent
c. Coal oil
d. Solvent - CORRECT ANSWER✔✔A
Which of the following emissions is NOT considered a gaseous pollutant?
Select one:
a. Nitrogen
b. Methane
c. Sulphur oxides