NCC Electronic Fetal Monitoring
Certification Questions with Correct
Answers
Which of the following factors can have a negative effect on uterine blood flow?
a. Hypertension
b. Epidural
c. Hemorrhage
d. Diabetes
e. All of the above
e. All of the above
How does the fetus compensate for decreased maternal circulating volume?
a. Increases cardiac output by increasing stroke volume.
b. Increases cardiac output by increasing it's heart rate.
c. Increases cardiac output by increasing fetal movement.
b. Increases cardiac output by increasing it's heart rate.
Stimulating the vagus nerve typically produces:
a. A decrease in the heart rate
b. An increase in the heart rate
c. An increase in stroke volume
NCC Electronic Fetal Monitoring Certification
2026/2027: Questions
NCC Electronic
with Correct
Fetal
Step-by-step
Monitoring
Answers.pdf
explanations
Certification Questions with Correct Answers.pdf //Step-by-step explanations
,Step-by-step explanations:- Page 2 of 116
NCC
NCCElectronic
ElectronicFetal
FetalMonitoring
MonitoringCertification
CertificationQuestions
Questionswith
withCorrect
CorrectAnswers
Answers.pdf 2026// Step-by-step explanations
d. No change
a. A decrease in the heart rate
What initially causes a chemoreceptor response?
a. Epidurals
b. Supine maternal position
c. Increased CO2 levels
d. Decreased O2 levels
e. A & C
f. A & B
g. C & D
g. C & D
The vagus nerve begins maturation 26 to 28 weeks. Its dominance results in what effect to the FHR
baseline?
a. Increases baseline
b. Decreases baseline
b. Decreases baseline
T/F: Oxygen exchange in the placenta takes place in the intervillous space.
True
T/F: The parasympathetic nervous system is a cardioaccelerator.
False
NCC Electronic Fetal Monitoring Certification
2026/2027: Questions
NCC Electronic
with Correct
Fetal
Step-by-step
Monitoring
Answers.pdf
explanations
Certification Questions with Correct Answers.pdf //Step-by-step explanations
,Step-by-step explanations:- Page 3 of 116
NCC
NCCElectronic
ElectronicFetal
FetalMonitoring
MonitoringCertification
CertificationQuestions
Questionswith
withCorrect
CorrectAnswers
Answers.pdf 2026// Step-by-step explanations
T/F: Baroreceptors are stretch receptors which respond to increases or decreases in blood pressure.
True
T/F: There are two electronic fetal monitoring methods of obtaining the fetal heart rate: the ultrasound
transducer and the fetal spiral electrode.
True
T/F: Variability can be determined with the fetoscope.
False
T/F: Because the ultrasound transducer and toco transducer are sealed units, they can be dipped in
warm water to make cleaning easier.
False
T/F: The most common artifact with the ultrasound transducer system for fetal heart rate is increased
variability.
True
T/F: All fetal monitors contain a logic system designed to reject artifact.
True
T/F: The monitor should always be tested before starting a tracing, either external or internal mode and
labeled a test.
NCC Electronic Fetal Monitoring Certification
2026/2027: Questions
NCC Electronic
with Correct
Fetal
Step-by-step
Monitoring
Answers.pdf
explanations
Certification Questions with Correct Answers.pdf //Step-by-step explanations
, Step-by-step explanations:- Page 4 of 116
NCC
NCCElectronic
ElectronicFetal
FetalMonitoring
MonitoringCertification
CertificationQuestions
Questionswith
withCorrect
CorrectAnswers
Answers.pdf 2026// Step-by-step explanations
True
T/F: The paper speed on the fetal monitor should always be set at 1cm/min.
False
T/F: Both internal and external monitoring methods are equally accurate means of obtaining the fetal
heart rate and contraction patterns.
False
T/F: The external toco is usually placed over the uterine fundus to pick up contractions.
True
T/F: The external toco gives measurable uterine pressure.
False
T/F: The fetal spiral electrode can be placed when vaginal bleeding of unknown origin is present.
False
T/F: The ultrasound transducer is usually placed on the side of the uterus over the baby's back, as the
fetal heart is heard best there.
True