The sensor of the temperature measuring device shall be
submerged a minimum of _____ in. [_____mm] into the
freshly mixed concrete. Ans: 3 in. [75 mm]

The temperature measuring device shall have a capacity
of measuring temperature of freshly mixed concrete to +-
_____ degrees F [+- _____ C] throughout a range of _____.
Ans: 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50
C]

The temperature measuring device shall be calibrated
_____, or whenever there is a question of _____. Ans:
Annually, accuracy

The temperature of concrete may be measured in a
wheelbarrow. True or False? Ans: True

The temperature of concrete may be measured in a wall
form. True of False Ans: True

A composite sample of concrete is required even if the
only purpose for obtaining the sample is to determine
temperature. True of False? Ans: False

What must be done to the sample container prior to
sampling the concrete? Ans: Dampen (with water)

© 2025 All rights reserved

, 2 | Page



What must be done to the concrete surrounding the
temperature measuring device after the device is
submerged in the fresh concrete. Ans: Gently press the
concrete around the temperature measuring device at the
surface of the concrete

How long must the temperature measuring device remain
in the freshly mixed concrete? Ans: At least 2 minutes
but not more than 5 minutes

After the temperature of the concrete is read, what is
required? Ans: Reporting of temperature

The temperature of concrete is reported to the nearest
_____ degrees F [_____ C] Ans: 1 degree F [0.5 C]

According to ASTM C1064, what is one reason to take the
temperature of concrete? Ans: Verify conformance to a
specified requirement for temperature of concrete

A maximum temperature of freshly mixed concrete is
specified in ASTM C1064. True of False? Ans: False

The sample of concrete used for temperature
determination must be rodded 25 times. True or False?
Ans: False

Sampling by this method is required when tests are to be
made to determine _____ with specification requirements.
Ans: Compliance

This method covers sampling from four types of
mixtures which are _____, _____, _____, and _____. Ans:

© 2025 All rights reserved

, 3 | Page



Stationary mixers, paving mixers, revolving drum mixers,
and open top mixers

The maximum allowable time between obtaining the first
and final portions of a composite sample is _____
minutes. Ans: 15

Portions of a composite sample shall be thoroughly
remixed bfore beginning tests on the sample. True of
False? Ans: True

The maximum elapsed time allowed between obtaining
the final portion of the composite sample and beginning
the tests for slump, temperature, and air content is _____
minutes. Ans: 5

The molding of strength test specimens shall begin
within _____ minutes after fabricating the composite
sample. Ans: 15

The concrete sample must be protected from
contamination and _____. Ans: Rapid evaporation

The minimum size sample for making strength test
specimens is _____. Ans: 28 L (1ft^3)

When sampling from a stationary mixer, the batch must
be sampled at _____ or more regularly spaced intervals
during discharge of the middle portion of the batch Ans:
2




© 2025 All rights reserved

Document information

Uploaded on
January 4, 2026
Number of pages
18
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Axpert
3.8
(127)
Sold
567
Followers
168
Items
29666
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions