✔✔Caulking - ✔✔Process of joining the joints and connections of cast iron pipes.

✔✔Motor Oil - ✔✔Type of oil used when threading GI pipes.

✔✔Centrifugal Pump - ✔✔Type of pump used for high-rise or mid-rise buildings, when
booster or piston pumps are unavailable or inadequate.

✔✔Piston Pump - ✔✔Type of pump used for residential or low-rise buildings, and
comes in single action, double action or twin.

✔✔Drum Trap - ✔✔Type of trap that is installed only in bathtubs.

✔✔Flushometer Valve - ✔✔Type of flushing valve used in commercial water closets,
usually installed with a pressure tank that expels air pressure and a set amount of water
when flushing.

✔✔14 - ✔✔Number of teeth per inch in a hacksaw blade used to cut GI pipes.

✔✔Looped Vent - ✔✔Type of vent used in an island counter type kitchen sink.

✔✔Trap Seal - ✔✔Maximum vertical depth of liquid that a trap can contain.

✔✔Sump Pit - ✔✔Type of detention pit usually found in basements, used to gather and
discharge waste water, sometimes with the help of a pump.

✔✔Standpipe - ✔✔Vertical pipe that is used for the storage of water, usually contains
pressure and is used for fire suppression.

✔✔Return Bend - ✔✔Type of pipe with a 180 degree bend.

✔✔2 - ✔✔Water Supply Fixture unit of a bath tub.

✔✔2 - ✔✔Water Supply Fixture unit of a shower

✔✔38 mm - ✔✔Diameter of pipe used for bath tub drum traps. (Max Fajardo, p. 172)
(mm)

✔✔38 mm - ✔✔Diameter of pipe used for wash basins / lavatories. (Max Fajardo, p.
172) (mm)

✔✔75 mm - ✔✔Diameter of pipe used for water closets. (Max Fajardo, p. 172) (mm)

,✔✔50 mm - ✔✔Diameter of pipe used for floor drains. (Max Fajardo, p. 172) (mm)

✔✔Bleeder - ✔✔Type of connection found in a looped vent, connecting the looped vent
pipe to the waste pipe.

✔✔50% - ✔✔Percentage required of liquid flow for a waste or soil pipe to have
adequate drainage or discharge.

✔✔Circuit Vent - ✔✔Type of vent that connects a battery of fixtures to a stack vent.

✔✔Privy - ✔✔A concrete sealed vault with a wooden shelter constructed for the
collection of raw sewage.

✔✔Cesspool - ✔✔Hole in the ground curbed with stones, bricks, CHB or other materials
to allow raw contaminated sewage to leach into the ground.

✔✔Trap Seal Loss - ✔✔A common problem in traps due to inadequate ventilation.

✔✔Unit Vent - ✔✔Type of vent that is shared by two fixtures of the same type.

✔✔Solvent System - ✔✔Type of system used in plumbing that eliminates the vent
stack, relying of downward pressure and suction.

The waste and sewage discharges form slug-like (bullet) pressings or pressure.

✔✔volume/flow rate - ✔✔Formula for detention time of a tank

✔✔national master plumbers association of the philippines - ✔✔NAMPAP

✔✔shut off valve - ✔✔a gate valve normally used to shut off flow of water from supply
pipe

✔✔key cock - ✔✔a faucet normally turned 90 degrees to open or close

✔✔indirect system - ✔✔overhead tank water distribution system is a _____ system

✔✔jack pump - ✔✔pump normally used for farm purposes

✔✔centrifugal rotary - ✔✔pumps with turbines

✔✔building design
occupants
heating capacity - ✔✔things to consider when sizing the hot water tank

,✔✔4"? - ✔✔minimum house drain diameter

✔✔.5 - ✔✔pipe sleeves must be ___ x the size of a pipe they protect

✔✔lead - ✔✔cleanout plugs must be made of

✔✔2 - ✔✔minimum " for underground drainage pipe

✔✔100 - ✔✔temperature needed to be considered hot water ___ C

✔✔bedpan washer - ✔✔aka clinical sink

✔✔2 - ✔✔minimum water service connections for hospital

✔✔backflow prevention device - ✔✔sillcocks require a ____

✔✔private water source - ✔✔a well is considered mostly as a ____

✔✔6 - ✔✔maximum distance in ft a 2 in trap from its vent

✔✔.02 - ✔✔maximum allowable % for soldered connections with lead pipe joints

✔✔8 - ✔✔maximum allowable % for soldered connections with lead

✔✔12 - ✔✔minimum ' clearance infront of a cleanout

✔✔10 - ✔✔minimum ' clearance from a terminal and a window opening in a building

✔✔6 - ✔✔maximum pipe side diameter not needing an effing manhole

✔✔1" - ✔✔recommended size of MWSS for service pipe in 2 storey residential

✔✔3/4 - ✔✔minimum water supply size for flush valve urinal

✔✔1 - ✔✔minimum water supply pipe diameter size " for flushometer valve water closet

✔✔1/2 - ✔✔minimum water supply pipe diameter size " for water closet without
flushometer valve

✔✔potability - ✔✔first steps in selecting water source

✔✔residence - ✔✔class 1 type occupancy water supply

, ✔✔restricted use - ✔✔class 2 type occupancy water supply

✔✔unrestricted use - ✔✔class 3 type occupancy water supply

✔✔permanent temporary - ✔✔what makes up total hardness

✔✔greensand filtraiton - ✔✔treatment of wells for acidity

✔✔marblestone filtration - ✔✔treatment for waste water

✔✔whitesand filtration - ✔✔treatment for swimming pool treatment

✔✔algae - ✔✔cause of objectionable tastes and odor of water

✔✔service pipe - ✔✔pipe from the street water main to the building served

✔✔GV WM CV - ✔✔order of valves for water connection

✔✔building supply pipe - ✔✔pipe carrying potable water from the water meter to a
building or other point of use or distribution

✔✔fixture supply - ✔✔water supply pipe connecting the fixture with the fixture branch

✔✔unit vent - ✔✔vent installed so that one vent pipe serves two traps

✔✔circuit vent - ✔✔a group vent which starts infront of the extreme fixture connection
on a horizontal branch and connects to the vent stack

✔✔looped vent - ✔✔vent used for islands and lavatories away from the wall and vent
branch

✔✔pump circuit system - ✔✔system used to produce a more efficient circulation of hot
water to the upper floor levels of a multi storey building

circulation of hot water by means of mechanical device

✔✔zdownfeed & gravity return system - ✔✔system of where hot water rises on the the
highest point of the plumbing system and travels to the fixture via gravity

✔✔relief vent - ✔✔A vent to relieve the pressure ahead of moving effluent in a
horizontal fixture branch.

Document information

Uploaded on
January 4, 2026
Number of pages
39
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK
3.5
(41)
Sold
287
Followers
11
Items
36005
Last sold
4 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions