Questions Solved 100% Correct | Verified Answers
Water line is installed minimum 12" above sewer line at highest point -
ANSWER -Water service separation distance is not required if:
50' - ANSWER -Distance for a septic tank/sewer to a private water
supply(well) is:
6"below the roof with an approved fitting - ANSWER -Where frost
closure is common an increase in vent size shall take place:
"V" zone (subject to wave heights in excess of 3') - ANSWER -High
Hazard flood zone is:
8.0% Lead - ANSWER -Lead free pipe and fittings contain less than:
110 degrees - ANSWER -Hot water is water at temperature greater than
or equal to:
0.2% Lead - ANSWER -Lead free solder and flux contain no more than
0.5 inches - ANSWER -Strainer plates on drain lines for rodent
proofing must have openings:
Two pipe size greater than the pipe passing through it - ANSWER -
Sleeves for pipes passing through foundation walls or under footings
shall be:
, 500' - ANSWER -Travel distance to toilet facilities in
merchantile/occupancies are:
300' - ANSWER -Travel distance to toilet facilities in covered malls
are:
15" - ANSWER -Water closets, bidets or lavatories shall have a
clearance from center of fixture to wall of:
21" - ANSWER -The required clearance from front of fixture to a wall,
door or other fixture is:
3" - ANSWER -Minimum size floor drains for public laundries or
central washing facilities is:
1 1/2" - ANSWER -Shower waste outlets shall be minimum of:
3" - ANSWER -Minimum size removable strainer for shower
compartments are:
.25 inches - ANSWER -Minimum size floor drain strainer opening is:
4 pounds per square foot - ANSWER -Sheet lead shall not weigh less
than:
12 ounces per square foot - ANSWER -Sheet copper shall not weigh
less than:
67% - ANSWER -Urinals shall not be substituted for more than what
percent of water closets?