Sprinkler System S-12

2nd Notification for Fire Department - ANS -the work or repairs cannot be completed and the system restored to service
within 8 hours of the time the system was placed or went out of service
\3rd Notification for Fire Department - ANS -With respect to a fire alarm system, the work or repairs will require the fire
alarm system to be out of service for more than 8 hours in any 24 hour period
\4th Notification for Fire Department - ANS -One or more other fire protection systems in the area in which a fire protection
system is out of service are or will also be out of service at the same time.
\A CCTV camera that is stalled inside a shell that resembles a sprinkler head is an example of... - ANS -A device similar
to fire protection equipment
\A sprinkler system - ANS -is a fire extinguishing system, that utilizes water as the extinguishing agent
\A supply of at least ______ extra sprinkler heads shall be kept available on the premises, to replace promptly any fused
or damaged sprinklers - ANS -Six
\Any head which has opened or has been damaged shall be replaced immediately with sprinkler head of similar
characteristics such as? - ANS -Operating temperature, orifice size, deflector orientation and thermal sensitivity
\At least once every______, the fire department connection for a sprinkler system shall be subjected to a hydro static
pressure test to demonstrate its suitability. - ANS -5 years
\Bronx Telephone Number - ANS -718-430-0200
\Brooklyn Telephone Number - ANS -718-965-8300
\By competent authority holding a S-12 certificate - ANS -Automatic and non automatic sprinkler systems shall be
inspected, tested, and maintenance
\detailed records - ANS -shall include information relative to conditions of water supply, gravity, and pressure tanks, levels
therein, valves, risers, piping, sprinkler heads. record shall be READILY AVAILABLE to any representative
\Drain test results - ANS -shall be posted on the tag indicating both the static and flow pressures before and after the
system was placed in an out of service condition
\Email - ANS -

, New York City Fire Department
Bureau of Fire Prevention
Fire Suppression Unit 3rd floor
9 Metro Tech Center
Brooklyn, NY 11201
\Fire Department notifications for out of service conditions - ANS -notification that a sprinkler system or fire alarm system,
or any part thereof, is or will be out of service shall be made to the fire department
\Fire guard - ANS -Under 50,000 the impairment coordinator can act as guard for the first 4 hours.
Greater than 50,000 guard required for every 50,000 thereafter
\Identifying OOS systems using discs/tags - ANS -Systems that are out of service shall be immediately identified by
placing a tag at each of the following locations: Fire department connections, system control valves, fire command center
or other clearly visible location in the lobby of the building
\If no impairment is found in the entire system green tags will be placed on the ________ ___________ __________ -
ANS -Main control valve
\Impaired equipment - ANS -underground service mains, water storage tanks, fire department connections, control valves,
fire and or booster pumps, that are out of service and are considered vital to part of the system that are required to be
tagged
\Impairment Coordinator - ANS -The person responsible for ensuring that proper safety precautions are taken when a fire
protection system is placed out of service. The building owner shall assign an impairment coordinator to comply with the
requirements of this section. In the absence of a specific designee, the owner shall be considered the impairment
coordinator.
\Manhattan Telephone Number - ANS -212-570-4300
\Master Plumber - ANS -is limited to residential occupies 30 sprinkler heads or less without a booster jump,
\Minor defect - ANS -If it is not corrected within 30 days it shall be deemed to be an impairment and reported in writing to
FD.
\National Fire Protection Association - ANS -What does NFPA stand for? Personally supervise inspection, testing,
servicing and maintenance of sprinkler systems
\Notification for Fire Department - ANS -Notification for Fire Department The sprinkler system or fire alarm system is or
will be out of service on more than one floor or building

Document information

Uploaded on
April 13, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ALICE12
3.9
(33)
Sold
141
Followers
16
Items
2062
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions